Model 6220/6221 Reference Manual
Delta, Pulse Delta, and Differential Conductance
5-45
Return to
4.
Perform one the following steps to configure Pulse Delta: Step I for Fixed
output, or step II for Sweep output. “
” are explained
I.
Fixed output
– On the Model 6221, press
CONFIG
and then
PULSE
to
access the CONFIG PULSE DELTA menu.
a.
Set I-HI, I-LO, pulse WIDTH, COUNT, RANGING, source delay (SRC
DEL), INTERVAL, disable (
NO
) the SWEEP function, and set the num-
ber of low measurements (LOW MEAS) to perform.
b.
When finished configuring the Fixed output, use the
EXIT
key to back
out of the menu structure.
II.
Sweep output
– Two configure processes are required for Sweep output:
a.
On the Model 6221, press
CONFIG
and then
PULSE
to access the
CONFIG PULSE DELTA menu. Use this menu to set pulse WIDTH,
COUNT, set the number of low measurements (
LOW MEAS
) to per-
form, and enable (YES) the SWEEP function. When finished, use the
EXIT
key to return to the normal display state.
b.
On the Model 6221, press
CONFIG
and then
SWP
to access the
CONFIGURE SWEEPS menu. Use the TYPE menu item to select and
configure the sweep (including the sweep delay), and use the SOURCE
RANGING menu item to select ranging (
BEST
,
FIXED
or
AUTO
). When
finished, use the
EXIT
key to return to the normal display state.
5.
Set the measurement units.
The basic Pulse Delta reading is in volts (which is the default units setting).
However, it can instead be expressed (and displayed) as an Ohms, Watts or
Siemens reading. With Watts as the selected units, the reading can be a
Peak power reading or an Average power reading. See
for details.
To set the measurement units, press the
UNITS
key to display the
READING UNITS
menu. Select
VOLTS
,
OHMS
,
WATTS,
or
SIEMENS
.
When
WATTS
is selected, you will then be prompted to select the power
units type:
AVERAGE
or
PEAK
. Measurement units can be changed while
Pulse Delta is running.
6.
On the Model 622x, press the
PULSE
key to arm Pulse Delta.
Details on the “
” are provided on
. The Model
622x is armed when the message “PULSE MODE ARMED Press TRIG to
start” or “PULSE SWEEP ARMED Press TRIG to start” is displayed briefly
and the ARM annunciator turns on.
7.
On the Model 6221, press the
TRIG
key to start taking Pulse Delta readings
and send them to the buffer.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
Summary of Contents for 6220
Page 16: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Page 24: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Page 453: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...