62
•
Using the DAS-1700 Series with DriverLINX
Keithley DAS-1700 Series
-6
-4
-2
0
2
4
6
-2048
2047
Bipolar
0
2
4
6
8
10
0
4095
Unipolar
DAS-1700 Series native Analog Input Codes versus Voltage Range (except HR models).
DriverLINX refers to the default hardware analog-coding scheme as the “native”
format. For computer arithmetic in a higher level language, the integer, or two’s
complement, format is generally easier to use. For unipolar data, native and integer
formats are identical.
Applications can use DriverLINX’s data conversion operations to transform an entire
data buffer from native format to many common integer and floating-point formats.