Keithley DAS-1700 Series
Using the DAS-1700 Series with DriverLINX
•
89
Multi-channel Digital Input List
Even though the DAS-1700
Series has only one digital
input channel, DriverLINX
supports specifying a channel
range for compatibility with
applications that use this
method
In multi-channel list mode, the DAS-1700 Series acquires all data from a random list
of digital channels.
•
The channel list may contain only one channel.
•
As the DAS-1700 Series only has a single digital input channel
available for reading, this technique is equivalent to Single Channel
Digital Input.
Digital Input Buffers
DriverLINX supports single-value, single-scan and buffered digital input.
•
For single-value input, specify the Number of buffers as
0
. The buffer
for a single value is the ioValue property.
•
For single-scan input, specify the Number of buffers as
1
and the
number of Samples equal to the number of channels.
•
For buffered input, specify the Number of buffers from
1
to
255
and
the number of Samples as desired.