36
•
Using the DAS-1700 Series with DriverLINX
Keithley DAS-1700 Series
Digital Input Subsystem Signals
The Digital Input subsystem has one 4 or 8-bit digital input port and two control
inputs which DriverLINX models as 1-bit logical digital input ports. DriverLINX
maps these signals to Logical Channels as shown in the following table:
Port
Connector Name
Logical Channel
4-bit digital input
DI 0 … DI 3
0
External clock alias
XPCLK
1
External trigger alias
TGIN
2
How DriverLINX maps digital input hardware channels to Logical Channels.
Digital Output Subsystem Signals
The Digital Output subsystem has a 4 or 8-bit digital output port and a group of
control signals that you can use as an output port. DriverLINX maps these signals to
Logical Channels as shown in the following tables:
Other Models
Port
Connector Name
Logical Channel
4-bit digital output
DO 0 … DO 3
0
5-bit digital output
MUX4 – MUX7, GEXT
1
How DriverLINX maps digital output hardware channels to Logical Channels of other models.
Counter/Timer Subsystem Signals
The Counter/Timer subsystem has one or two counter/timer channels for analog
input/output pacing. It also has an external clock source and a gate input that the
board can use with any Logical Channel. DriverLINX maps these signals as shown in
the following table:
Timer
Connector Name
Logical Channel
Input Pacing Counter
XPCLK
0
Output Pacing Counter
(AO models only)
XPCLK
1
How DriverLINX maps counter/timer hardware channels to Logical Channels.
StockCheck.com