Keithley DAS-1700 Series
Using the DAS-1700 Series with DriverLINX
•
87
Digital Input Channels
The DAS-1700 Series allows applications to specify the digital channels using three
techniques:
•
Start Channel—Acquire data from a single channel.
•
Start/Stop Channel Range—Acquire data from a consecutive range of
channels.
•
Channel List—Acquire data from a list of channels.
Digital Input Logical Channels
The DAS-1700 Series has a single digital input port that DriverLINX designates as
Logical Channel 0. DriverLINX defines two additional Logical Channels for the
external clock and trigger signals but applications cannot directly read their values.
DriverLINX defines the following Logical Channels for the DAS-1700 Series digital
inputs:
Logical
Channel
DriverLINX Function
DAS-1700 Series
External Connector
0
Standard Digital Input
DI 0 … DI 3
1
External Clock
XPCLK
2
External Trigger
TGIN
Single Channel Digital Input
In single channel mode, the DAS-1700 Series acquires all data from one channel.
How to set up the DAS-1700 Series to read from a single channel.