Relays
The T20 timer houses 2 relays. The contacts of both relays are voltage free and
are normally open. The relays are marked Relay 1 and Relay 2 on the terminal
block. Relay 1 is the primary relay and is used to control the pump motor. It has
an electrical rating of 30 Amps (resistive) at 240VAC. Relay 2 is a 16 Amp (resis-
tive) 240VAC rated relay and is used for actuating an external alarm. The relays
built into the T20 timer are not suitable for the direct control of DC motors.