13
Air Overrun Function
The system has an air overrun function which allows the air to continue to operate for approximately 1 second after the
water flow stops. This function purges the water from the shower head, reducing the build up of limescale.
Fan Overheat Protection
In the unlikely event of the fan overheating from being obstructed with debris or being continuously run in a hot environ-
ment, then a protection mode will be triggered with reduced fan speed and fast LED flash on Hub. The fan will return to
normal operation once debris is cleared or the temperature returns to operational level.
Fan Test Function
Press and hold the
Blower fan speed
button to run the fan independently of full shower operation.
Time Delay Feature
•
The factory setting is set at
30 seconds (3 LED Flashes)
•
Press TMR button once, the number of LED flashes next to the button indicate what timer setting the Control Hub is
currently set at. (There are 7 timer settings: 10s, 20s, 30s, 45s, 60s, 90s & 120s)
Operation
1.
Turn on the water isolation valve.
2.
Turn on the electricity supply.
3.
Check the shower panel is powered.
4.
To operate, press the timed flow sensor button. Both air and water should flow from the showerhead.
5.
If a mixer is present, the temperature can be increased by rotating the control knob clockwise. The temperature can
be decreased by rotating the control knob anti-clockwise.
Congratulations, you’re now ready to experience the greenest shower in the world and start saving water and
energy costs!
Factory Settings