Operating Manual AmbiCube
Operation
Page 20 of 40
Version: 2 | en
Subject to technical changes
7 Operation
7.1 Ready for use condition
When ready for operation, the room air cleaner is switched off and connected to
the power supply system. In this state, the room air cleaner can be switched on at
any time by turning the selector switch to position I.
Procedure to set the room air cleaner into operational condition:
ü
The brakes of the four castors are activated.
ü
The flat end of the supplied connection cable is connected to the correspond-
ing connector on the rear side of the room air cleaner.
ü
The selector switch on the front of the room air cleaner is in position 0
u
Connect the round plug of the power supply connection cable to the grounding
contact socket.
ð
The room air cleaner is in ready-to-operate condition.
7.2 Switching on the room air cleaner
ü
The room air cleaner is in ready-to-operate condition.
1.) Make sure that there are no objects in front of the air intake openings.
2.) Make sure that there are no objects on the air outlet opening.
3.) Turn the selector switch on the front of the room air cleaner to position I.
Selector switch room air cleaner On / Off
Manometer filter resistance
Potentiometer for speed of fan
Illustration 7:
Detail view of the control unit of the room air cleaner
Ä
The fan is activated and the room air cleaner is in operation.
4.) Wait until the fan has completely started up. This can be recognized by the op-
erating noise.
5.) Read the indicated filter resistance on the manometer on the front of the room
air cleaner. The room air cleaner works correctly if the displayed value is less
than 8.5 mbar. If the displayed value is higher, the cause of the deviation must
Maximum filter resistance exceeded [
.
ð
The room air cleaner is in operation.
7.3 Switching off the room air cleaner
ü
The room air cleaner is switched on and in operation.
u
Turn the selector switch on the front of the room air cleaner to position 0.