background image

 

 

For constant run applications in daily use or units subjected to extremely 

heavy use, change oil monthly.  

 

Air Filter: 

 

-

 

Check and clean air filter every month, making sure the filter is free from debris 

and functioning properly.   

-

 

Replace filter element every 1500 hours or every year, whichever occurs first.  

 

Maintenance Intervals: 

 

-

 

Check and record each maintenance task in the table below. 

 

 

 

 

Please Download, Read, And Review The Full Operations Manual For 

Your Compressor At: 

 

 

 

 

 

  

 

 

 

15 

 

 

Cleaning the air filter   

Maintenance intervals 
 

We recommend servicing and maintaining your compressor at the following intervals. The hours 
of operation refer to average working conditions. Other intervals may apply depending on these 
conditions. Please contact LAPLANTE in this event. 

 

 

 
Please record each maintenance task in the table on the last pages of these instructions! This may 
help 

LAPLANTE-Service

 to locate faults if any occur. 

 

Maintenance intervals dependent on usage 
either after 

or 

Maintenance work 
 

Operating hours 

weekly / monthly 

yearly 

Check  oil  level  and 
top up, if necessary 

 

weekly 

 

Check  suction  filter 
and clean, if necessary 

500 

monthly 

 

Replace  suction  filter 
cartridge 

2000 

 

Check safety valve 

2000 

 

Check  cooler  for 
soiling  and  clean,  if 
necessary 

500 

monthly 

 

Change oil * 

1.000 

 

every 1 years 

Check  V-belt  for 
damage and replace, if 
necessary 

2.000 

 

 

www.kellogg-american.com

 

All manuals and user guides at all-guides.com

Summary of Contents for V8071-205

Page 1: ...w kellogg american com INSTRUCTION MANUAL Industrial Series Piston Air Compressor Model Number V8071 205 Part Number 001030 Pump Model LP205 Motor 7 5 HP 1 PH Air Tank 80 Gal Vertical L001152KNA V8073...

Page 2: ...ipment for damage 2 If the shipment is damaged the customer should note so on the freight bill 3 The Customer should request an inspector from the freight company to inspect the equipment immediately...

Page 3: ...e the automatic control system is operating within the proper limits 9 Periodically check all safety and relief devices for proper operation 10 Do not play with compressed air Pressurized air can caus...

Page 4: ...connecting anything to the motor or compressor will pay dividends in long term trouble free operation Installation Instructions Inspection Check for possible damage in transit and see that the pulley...

Page 5: ...e starting fill crankcase to the high level mark on the sight glass with Kellogg American oil meeting the following specifications For operation in damp or humid conditions addition of rust inhibitor...

Page 6: ...nt industrial lubricant with rust and oxidation inhibitors specifically formulated for reciprocating compressors Normal break in period of Kellogg air compressors is 25 hours After which the compresso...

Page 7: ...ours of operation refer to average working conditions Other intervals may apply depending on these conditions Please contact LAPLANTE in this event Please record each maintenance task in the table on...