Kelly KLS-8080N/NPS Sinusoidal BLDC/PMSM Controller User’s Manual
V1.24.1
31
Please check whether the Identification Angle item is at 85 or not. It is correct if identification
angle item is at 85.
5,Please fill 170 in the identification angle item. And please click the write button. The user
program will give a pop-up window which show the Write operation is successful. Please quit
from the user program. Please turn off the power supply.
6,Please turn on the power supply after the power supply is off for a few seconds. The motor
shaft will try to run on directions randomly. It is normal because the controller is doing
Identification angle operation.
7,Please wait about 2-3 minutes.
8,If the identification angle operation is finished, the motor will stop completely. Please try to
reset the power and try to connect the controller to user program or APP again. And you will see
reset error message in the monitor screen of user program.
9,Please turn off the power supply again. Please wait about a few seconds to turn on the power
supply one more time.
10,Please try to connect the controller to user program again. You will see 85 in the
identification angle item. That is to say, the controller identification angle operation is successful.
You can use the KLS-8080N controller to drive the motor now.