Kelly Jaguar series KLS-N Sinusoidal Brushless PM Motor Controller User’s Manual
V1.21
23
way. The motor speed will increase when the throttle is from 0V to 5V.
If you enable joystick for this controller in user program, you will start the motor from 2.5V
position.2.6V to 5V is forward.2.4V to 0V is backward.
2.4V to 2.6V is the throttle dead zone. Customers can adjust the throttle dead zone in user
program also.
Please note the common throttle will spring back to original position if you release the throttle.
Suggestion: factory default is Disable.
(23)Three Gears switch: It is used for function of F-N-R control.
Please check the wiring diagram in the manual for F-N-R control.
Suggestion: Set according to the practical situation, factory default is Disable.
(20-A)Three Gears Switch
Value range: Enable and Disable
Functional description: If enabled, the Forward switch will be activated. Please see figure 4.1.
Suggestion: Set according to the practical situation, factory default is Disable.
(20-B)Foot Switch
Value range: Enable and Disable
Functional description: If enabled, the foot switch will be activated. The controller will not accept
the throttle signal if the foot switch is turned off. Please see figure 4.1.
Suggestion: Set according to the practical situation, factory default is Disable.
Configuration
Pin Status
Running
Status
Forward
Switch
Foot Switch FWD_SW
(12)
REV_SW
(14)
Foot
(15)
Enable
Disable
OFF
OFF
x
Neutral
OFF
ON
x
Reverse
ON
OFF
x
Forward
ON
ON
x
Neutral
Disable
Enable
x
OFF
OFF
Can’t operate
x
ON
OFF
Can’t operate
x
ON
ON
Reverse
x
OFF
ON
Forward
Disable
Disable
x
OFF
x
Forward
x
ON
x
Reverse
Note: X means can be on or off
Figure 4.2
(24)Boost: If enabled, the controller will output max power for a while.
Boost function is just full throttle position when you turn on boost switch even if the throttle is not
operated at all.