GROUND BALANCE
Automatic GROUND BALANCE may be used in all search modes and is performed as
follows:
1. Perform Automatic GROUND BALANCE procedure in location where there is no metal
present;
2. While keeping search coil parallel to the ground, push and hold GROUND BALANCE dial
and begin pumping the search coil up and down repeatedly from about 15 - 20cm (6''- 8'')
above the ground down to 3 - 6cm (1''-2”) above the ground maintaining smooth, even
movement of coil;
3. Continue pumping coil until detector emits a beep tone which indicates completion of
GROUND BALANCE sequence. Depending on ground conditions, it typically takes about
2-4 pumps for the ground balance sequence to complete.
4. In the event GROUND BALANCE sequence described above does not result in
completion beep tone, please move to another nearby location and retry GROUND
BALANCE procedure. Incomplete GROUND BALANCE sequence may occur if there is metal
under the search coil, the ground is too conductive (mineralized) or in rare cases if ground
is non-mineralized.
NOTE:
The
Au GOLD FINDER
will continue to ground balance and produce a beep tone
for as long as you keep the dial pressed.
RECOMMENDATION:
To ensure proper GROUND BALANCE, it is recommended that the
GROUND BALANCE sequence described above be performed 2-3 times prior to use of
detector.
Automatic GROUND BALANCE
Manual GROUND BALANCE should be used when
Au GOLD FINDER
will not complete
Automatic GROUND BALANCE sequence.
Conditions which may interfere with, or not suitable for the Automatic GROUND BALANCE
sequence to successfully complete include wet beach sands, soils/sands containing alkali,
salt or brine water, lands with high waste metal content (dump sites), recently plowed
fields, recently fertilized fields, highly mineralized grounds and grounds with very low
mineralization.
NOTE:
Manual GROUND BALANCE requires a skill which develops over time through
practice and experience. Once mastered, it becomes the preferred method for
professional detectorists.
Manual GROUND BALANCE
GROUND BALANCE can be performed three ways in
Au GOLD FINDER
: 1) Auto, 2) Manual
and 3) Tracking. GROUND BALANCE is a multi-function dial (rotary and push) used to
perform either Automatic or Manual GROUND BALANCE. Push and hold for setting Auto
GROUND BALANCE. Rotate to fine tune Manual GROUND BALANCE. The third GROUND
BALANCE option is TRACKING which is selected using the TRACKING toggle switch.
Page 12
Summary of Contents for GOLD FINDER
Page 1: ...USER MANUAL ...