13
Installation
SNA-Series Tankless Heater
Keltech •
215-1815 Rev. B; ECN 130011
10/17/2014
Troubleshooting using the Flow Limit Control Board (FLCB)
Problem
Solution
The heater does not work or works intermittently .
Check that the flow sensor located at the inlet is spinning
with water running . Check if in Low flow (> 1 .5 gpm) that
the FLCB light is on . If in High flow (> 15gpm) both the low
flow light and high flow lights will be illuminated .
Check that water flow through the heater is adequate to
activate the flow sensor at 1 .5gpm .
Check that the heater is wired with the proper breaker and
wire size . Refer to Table 1 for proper requirements
Check that the unit is receiving voltage from all 3 phases
of the power source . A load voltage reading is also helpful .
Element Load Bank 1–2 or 3–4 is not energized .
Check FLCB with corresponding light indicated:
Bank 1–2 on the front bezel = Bank 1 on the FLCB
Bank 3–4 on the front bezel = Bank 2 on the FLCB .
If the light is off and there is power on . Check if water
temperature is greater than 175˚F . Decrease water
temperatures and restart .
Follow the schematic to perform the following continuity checks:
Emergency stop switch .
Door guard .
High temperature bimetals (Manual Reset Safeties) .
Optional ground fault breaker must be in the closed position for the unit to work .
All internal breakers must be in the ON position for the unit to work .
For additional information on Troubleshooting or other information, please call Keltech Inc . technical support at
1-800-999-4320 . Please have Model No . and Serial No . available when seeking technical assistance . Serial No .
tag is located in the enclosure on the upper left hand corner of the back plate .
Please record and maintain this
information at all times:
SNA- Model No.
Serial No.
High Temp .
Limit Senser
Input
Bank 2 Over
Temp . (OT)
Bank 1 Over
Temp . (OT)
High Flow
Status
Low Flow
Status
Purge/Dump
(SNA Models
Only)