22
ELECTRICAL/REFRIGERATION SPECIFICATIONS
4DF-13 ELECTRICAL/REFRIGERATION SPECS
SYSTEM COMPONENTS - R-404A
SYSTEM PERFORMANCE -
(THERMOSTAT SET AT #4 POSITION)
Compressor
Americold
Compressor Horsepower
HP 110-1-3083
Recommended Operating Temp. Range
+10°F to -10°F
Cabinet Volts
115
Expansion Device
7' x .031
Charge Refrig. Type / Oz. / Grams
Refer to serial data plate located in unit compart
ment.
AMBIENT
70°F / 21.1°C
80°F / 27°C
90°F / 32.5°C
Cavity Temp. (F/C)
0
-1
-2
Suction Pressure (PSIG)
15
16
18
Discharge Pressure (PSIG)
256
289
323
Compressor Amps
1.5
1.5
1.6
Total Refrigeration Amps
1.6
1.7
1.7
100% Run
-25
-19
-11
NOTE: REFER TO SERIAL DATA PLATE FOR REFRIGERANT TYPE & CHARGE.
6DF-13 ELECTRICAL/REFRIGERATION SPECS
SYSTEM COMPONENTS - R-404A
SYSTEM PERFORMANCE -
(THERMOSTAT SET AT #4 POSITION)
Compressor
Americold
Compressor Horsepower
HP 117-1-3085
Recommended Operating Temp. Range
+10°F to -10°F
Cabinet Volts
115
Expansion Device
8' x .036
Charge Refrig. Type / Oz. / Grams
Refer to serial data plate located in unit compart
ment.
AMBIENT
70°F / 21.1°C
80°F / 27°C
90°F / 32.5°C
Cavity Temp. (F/C)
-2
-2
-4
Suction Pressure (PSIG)
10
11
13
Discharge Pressure (PSIG)
246
279
314
Compressor Amps
2.3
2.3
2.4
Total Refrigeration Amps
2.6
2.6
2.7
100% Run
-29
-20
-14