24
ELECTRICAL/REFRIGERATION SPECIFICATIONS
14DF-13 ELECTRICAL/REFRIGERATION SPECS
SYSTEM COMPONENTS - R-404A
SYSTEM PERFORMANCE -
(THERMOSTAT SET AT #4 POSITION)
Compressor
Americold
Compressor Horsepower
HP 127-1-3515
Recommended Operating Temp. Range
+10°F to -15°F
Cabinet Volts
115
Expansion Device
7' x .042
Charge Refrig. Type / Oz.
Refer to serial data plate located in unit compart
ment.
AMBIENT
70°F / 21.1°C
80°F / 27°C
90°F / 32.5°C
Cavity Temp. (F/C)
+2
+3
+2
Suction Pressure (PSIG)
12
14
15
Discharge Pressure (PSIG)
236
269
304
Compressor Amps
4
4
4.5
Total Refrigeration Amps
4.8
5.0
5.1
100% Run
——
14°F / -10°C
——
NOTE: REFER TO SERIAL DATA PLATE FOR REFRIGERANT TYPE & CHARGE.
NOTE: REFER TO SERIAL DATA PLATE FOR REFRIGERANT TYPE & CHARGE.
DI4-1 ELECTRICAL/REFRIGERATION SPECS
SYSTEM COMPONENTS - R-404A
SYSTEM PERFORMANCE -
(THERMOSTAT SET AT #4 POSITION)
Compressor
Americold
Compressor Horsepower
HP-110-1-3083
Recommended Operating Temp. Range
+10°F to -15°F
Cabinet Volts
115
Expansion Device
7' x .031
Charge Refrig. Type / Oz. / Grams
Refer to serial data plate located in unit compart
ment.
AMBIENT
70°F / 21.1°C
80°F / 27°C
90°F / 32.5°C
Cavity Temp. (F/C)
-7
-7
19
Suction Pressure (PSIG)
9
8
22
Discharge Pressure (PSIG)
221
240
332
Compressor Amps
1.3
1.3
1.7
Total Refrigeration Amps
1.9
1.9
2.2
Kwh / 24 hours
2.8
3.3
3.1
100% Run
——
-19°F / -28.5°C
——
Stat Position #1