background image

SERVICE/INSTALL MANUAL

IMPORTANT INFORMATION, 

KEEP FOR OPERATOR

PART NUMBER HB_738371_9F73837100, REV. A (03/23)

This manual provides information for:

BOTTLE COOLER

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, 
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS 
CONTAINED IN THIS MANUAL.

FOR YOUR SAFETY

 Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

NOTIFY CARRIER OF DAMAGE AT ONCE

 It is the responsibility of the consignee 

to inspect the container upon receipt of same and to determine the possibility 
of any damage, including concealed damage. Electrolux Professional, Inc. 
suggests that if you are suspicious of damage to make a notation on the 
delivery receipt. It will be the responsibility of the consignee to file a claim with 
the carrier. We recommend that you do so at once.

Manufacture Service/Questions 866-339-8515.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

 

Note these instructions apply to all coolers. Installations of equipment may not 
exactly correspond to your model. 
NOTICE: Due to a continuous program of product improvement, Electrolux 
Professional, Inc. reserves the right to make changes in design and specifications 
without prior notice. NOTICE: Please read the entire manual carefully before 
installation. If certain recommended procedures are not followed, warranty claims 
will be denied.

USA & Canada, 866-339-8515

4003 Collins Lane, Louisville, KY 40245

www.kelvinatorcommercial.com 

Information contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated product information and 

specifications. © 2023 Electrolux Professional, Inc. All Rights Reserved. 

EQUIPMENT DESCRIPTION

MODEL NO.

V/HZ/PH

AMPS

CAPACITY

STORAGE (CU FT)

HP

BTU

CHARGE OZ

SHIP WEIGHT LBS

NEMA PLUG

KCHBC36

115/60/1

1.8

10

3/8

2000

2.12

161

5-15P

KCHBC50

115/60/1

3.0

15

1/2

3200

2.47

310

5-15P

KCHBC65

115/60/1

3.0

20

1/2

5400

3.17

353

5-15P

KCHBC95

115/60/1

3.3

26

1/2

7600

3.53

439

5-15P

REV. B (11/23)

INSTALLATION

Make sure that the cooler is not damaged on arrival. Your supplier must be notified 
of any transport damage, within 24 hours of delivery.
The cooler should be placed in a warm, dry room, with suitable ventilation.
Place the cooler in such a way, as to allow the free circulation of air around it. That 
is, with at least 100mm space all around it.
Never place the cooler in strong sunlight. The cooler be placed on a level surface. 
Make sure that it does not rock.
If the cooler has been stored or transported cold, it must not be started before 
the compressor is judged to have reached a temperature at least 41°F. It is 
recommended to clean up the cooler before starting it.

ELECTRICAL CONNECTION

The cooler must be connected to a socket with the correct voltage/frequency, as 
show on the nameplate. The standard for u.s is 115V/50HZ. Voltage variations 
of ±10% are acceptable. Greater variations can damage the cooler, and in such 
cases the factory warranty is not valid. In the case of extreme voltage variation, 
above or below the standard, your local supplier will be able to advise you, what 
to do.
The cooler requires extra protection according to the Danish Heavy Current 
Regulations.
This also applies, if a new cooler is replaced, which did not have such protection. 
The purpose of extra protection, is to protect the user from dangerous electric 
shocks, in the case of defect.

 

 
 
 
 
 

 
 

 

 

BOTTLE COOLER

BOTTLE COOLER

BOTTLE COOLER

BOTTLE COOLER

                                                                                               

Service, Installation and Care Manual 

Please read this manual completely before attempting to install or operate this equipment. 
Notify carrier of damage!    Inspect all components immediately.   

 
 
 
 

 

 

IMPORTANT INFORMATION 

READ BEFORE USE 

PLEASE SAVE THESE INSTRUCTIONS!

 

 
 
 
 

Summary of Contents for KCHBC36

Page 1: ...MPS CAPACITY STORAGE CU FT HP BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG KCHBC36 115 60 1 1 8 10 3 8 2000 2 12 161 5 15P KCHBC50 115 60 1 3 0 15 1 2 3200 2 47 310 5 15P KCHBC65 115 60 1 3 0 20 1 2 5400 3...

Page 2: ...TE CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE NOTE THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL SENSORY OR...

Page 3: ...wait for 5 seconds to display the sensor value again 2 2 HOW TO CHANGE THE SETPOINT On A temperature alarm happened MAIN FUNCTIONS 1 How to See the Setpoint 1 Push and immediately release the SET key...

Page 4: ...ase call service personnel Inform them the nature of the problem the type of cooler serial number and item number provided on the nameplate at the back of the cabinet Do not open the cabinet as every...

Page 5: ...5 BOTTLE COOLER Wiring Diagram KCHBC36 KCHBC50 KCHBC65 CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515 Wiring Diagram KCHBC95 CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515...

Page 6: ...LER Wiring Diagram KCHBC36 KCHBC50 KCHBC65 CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515 Wiring Diagram KCHBC95 CALL FACTORY FOR REPLACEMENT PARTS 866 339 8515 POWER SUPPLY POWER SUPPLY L L N N 1 1...

Page 7: ...companies use of parts other than genuine Electrolux Professional Inc parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate po...

Page 8: ...8 BOTTLE COOLER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 9: ...U ONZAS DE CARGA PESO DE ENV O LB KG ENCHUFE NEMA KCHBC36 115 60 1 1 8 10 0 28 3 8 2000 2 12 161 73 5 15P KCHBC50 115 60 1 3 0 15 0 42 1 2 3200 2 47 310 140 6 5 15P KCHBC65 115 60 1 3 0 20 0 56 1 2 54...

Page 10: ...O DEL EQUIPO NOTA SE DEBE VIGILAR A LOS NI OS PARA IMPEDIR QUE JUEGUEN CON EL EQUIPO NOTA ESTE EQUIPO PUEDEN UTILIZARLO NI OS DE M S DE 8 A OS Y PERSONAS CON CAPACIDADES F SICAS SENSORIALES O MENTALES...

Page 11: ...he set point value Encendido Se produjo una alarma de temperatura PRINCIPALES FUNCIONES 1 C mo ver el ajuste de referencia 1 Presione y suelte de inmediato la tecla SET ajuste la pantalla muestra el a...

Page 12: ...servicio t cnico Inf rmeles de la naturaleza del problema el tipo de enfriador el n mero de serie y el n mero del equipo que figura en la placa de caracter sticas de la parte posterior del armario No...

Page 13: ...NFRIADOR DE BOTELLAS Diagrama de cableado KCHBC36 KCHBC50 KCHBC65 LLAME A LA F BRICA SI NECESITA REPUESTOS 866 339 8515 Diagrama de cableado KCHBC95 LLAME A LA F BRICA SI NECESITA REPUESTOS 866 339 85...

Page 14: ...rama de cableado KCHBC36 KCHBC50 KCHBC65 LLAME A LA F BRICA SI NECESITA REPUESTOS 866 339 8515 Diagrama de cableado KCHBC95 LLAME A LA F BRICA SI NECESITA REPUESTOS 866 339 8515 POWER SUPPLY POWER SUP...

Page 15: ...s de personas que no sean empresas de servicios autorizadas o causas externas como uso incorrecto o indebido alimentaci n el ctrica inadecuada accidentes incendios o desastres naturales 15 Los equipos...

Page 16: ...E BOTELLAS Registro de servicio N de modelo Adquirido a N de serie Ubicaci n Fecha de compra Fecha de instalaci n N de orden de compra Para llamadas al servicio t cnico Fecha Mantenimiento realizado R...

Reviews: