background image

6

Adjustable Temperature Control

The adjustable cold control is located on the top left side of the
evaporator housing inside the unit. “5” is the medium
(recommended) setting and “9” is the coldest setting.

Appliance Start-up

Once the appliance has been located in its permanent location
and the proper power and grounding has been provided, the
following items must be checked or completed:

Cool Down Period

For safe food storage, allow 24 hours for the appliance to cool
down completely before loading with food. The appliance will
run continuously for the first several hours. Do not place any
food in the appliance until after the first 24 hours of operation.

Defrost Setting

The appliance is designed to defrost automatically every 12
hours. To set the time of defrost, wait until the desired time to
defrost. With the notch on the timer knob aligned with the line
on the bracket (Fig. A), turn the defrost timer knob clockwise
slowly. The timer will click several times, then once loudly, at
which point the defrost cycle begins. The timer knob will advance
through the defrost cycle, then click loudly at the end of the cycle
(Fig. B). The appliance will defrost automatically every 12 hours
after the first defrost cycle.

Features

NSF and FDA Approved Adjustable Shelving

This appliance is provided with 

NSF

 and 

FDA

 approved heavy

duty epoxy powder coated adjustable shelves. The one with the
wires that are angled on the front and back goes on the floor of
the cabinet. The others are placed in the adjustable stainless
steel shelf supports that clip into the shelf support strips on each
side of the interior. Make sure to place the shallow shelf in the
upper-most position.

 

Front Fixed and Rear Swivel Casters

Glass door unit come with two (2) front fixed casters with
brakes and two (2) rear swivel casters. Non-glass door unit
comes with two (2) front swivel casters with brakes and two (2)
rear swivel casters. The casters allow the appliance to be
moved with ease and then locked in position at its desired
location.

Fig. A

Position of knob before

turning clockwise to start

defrost cycle (First click)

Fig. B

Position of knob at end

of defrost cycle (Second

click)

Appliance Placement

Leave a one (1) inch space on all sides and the back of the
cabinet for ease of installation, proper air circulation and electrical
connections. 

DO NOT block the front grill on the lower front

of your appliance

. Sufficient air circulation is essential for the

proper operation of your appliance. Choose a place that is near
a grounded electrical outlet. For the most efficient operation,
the appliance should be located where surrounding temperatures
will not drop below 40ºF (5ºC) or exceed 110ºF (43ºC). Additional
compressor heaters are not recommended.

Insulation

The insulated space of this cabinet is sealed to maintain peak
efficiency. Holes drilled in the cabinet may destroy that seal and
damage electrical wiring located in the insulated space.

DAMANGED ELECTRICAL WIRING OR WET INSULATION
CAUSED BY DRILLING WILL VOID THE WARRANTY.

Thermostat Setting

The appliance is shipped from the factory
with the thermostat set at about the mid-
point of the operating range. Adjustments
colder or warmer can be made after the
appliance has been running for at least
8 hours. Allow at least 8 hours for
temperature stabilization before re-
adjusting the thermostat.

Summary of Contents for KFS220RGW0

Page 1: ...al Information 3 Caster Installation and Setup Glass Door 3 4 Caster Installation and Setup Non Glass Door 5 6 Appliance Start up 6 Features 6 7 Routine Maintenance 7 Energy Conservation Measures 7 Troubleshooting Guide 8 9 Wiring Diagram 10 Warranty 11 READ AND SAVE THESE INSTRUCTIONS Electrolux Major Appliances 297147600 December 2006 ...

Page 2: ...essed PRODUCT REGISTRATION CARD shown above should be filled in completely signed and returned to the address provided Important Safety Instructions Read all instructions before using this appliance For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this unit or any other appliance Read product labels for flammability and other warnings Child Safe...

Page 3: ...the control to OFF turns off the compressor but does not disconnect power to other electrical components Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord A B D C F E A CASTER RAIL 2 E WASHER 4 B LOCKING NUT 8 F SPACER PLATE 2 C CARRIAGE BOLT 8 G SWIVEL CASTER 2 D BOLT 4 H FIXED CASTER W BRAKE 2 H G CASTER INSTALLATION A...

Page 4: ...front of caster rail Align the caster rail assembly with the right hand side of the unit Make sure the fixed caster is positioned toward the front of the unit Align the bolt with the threaded hole in the front right foot pad of the unit Thread the bolt into the hole until finger tight see Fig 5 Figure 5 WASHER WASHER BOLT BOLT REAR SWIVEL CASTER INSTALLATION Place a washer on one of the four long ...

Page 5: ...lastic leg levelers by turning it counterclockwise see Fig 2 CASTER RAIL INSTALLATION x Place a washer onto one of the six long bolts and slide bolt through the hole located at the front of caster rail x Align the caster rail assembly with the right hand side of the unit x Align the bolt with the threaded hole in the front right foot pad of the unit Thread the bolt into the hole until finger tight...

Page 6: ...port strips on each side of the interior Make sure to place the shallow shelf in the upper most position Front Fixed and Rear Swivel Casters Glass door unit come with two 2 front fixed casters with brakes and two 2 rear swivel casters Non glass door unit comes with two 2 front swivel casters with brakes and two 2 rear swivel casters The casters allow the appliance to be moved with ease and then lo...

Page 7: ...arm water and mild detergent or touch the residue with the sticky side of tape already removed DO NOT REMOVE THE SERIAL PLATE Condensate Pan Some models have a condensate pan in a fixed position located behind the toe grill This must not be removed from under the cabinet If the pan is removed condensate will drop onto the floor POWER FAILURE DO NOT open the appliance lid unnecessarily if the appli...

Page 8: ...r the temperature to stabilize Interior appliance temperature is too warm Temperature control is set too warm Turn control knob to a colder setting Allow several hours for the temperature to stabilize Door is opened too frequently or kept open too long Warm air entering the appliance causes it to run more Open the door less often Appliance door may be slightly See Door Problems Large amount of war...

Page 9: ...en too long or is opened too frequently Open the door less often Odors in appliance Interior needs to be cleaned Clean interior with sponge warm water and baking soda Foods with strong odors are in the appliance Cover the food tightly Door will not close Appliance is not level It rocks on the floor when it is moved slightly Level the appliance by putting wood or metal shims under part of the appli...

Page 10: ...pt to make repairs due to the possibility of electrical shock Disconnect the power cord before servicing IMPORTANT IF ANY GREEN GROUNDING WIRES ARE REMOVED DURING SERVICING THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY SECURED ELECTRICAL CIRCUIT STAINLESS STEEL DOOR REFRIGERATOR STAINLESS STEEL DOOR FREEZER GLASS DOOR REFRIGERATOR ...

Page 11: ...ly accidents fires or acts of God 17 Labor costs after ninety 90 days from your original date of purchase incurred for product repair or replacement as provided herein for appliances operated by a concessionaire or vendor in a trailer or other motorized vehicle or at varying locations Exclusions If You Need Service This warranty only applies in the USA and Canada In the USA your appliance is warra...

Reviews: