gate or ball
valve on inlet
filter
Remove the filter by turning it counterclockwise. Clean under
running water with an old toothbrush then replace.
1. Turn off the water inlet supply valve.
2. Open a hot water tap to release the line pressure.
NOTE: This filter is designed to be cleaned as part of
regular maintenance.
Kelvinator Gas Continuous Flow hot water system
water connection 11
Water connection
warning
Do not reverse the hot outlet and cold supply line
connections to the water heater as this will cause your
heater to operate improperly.
gate or ball
valve on inlet
drain plug
filter
• All pipes, pipe fittings, valves and other components,
including soldering materials, must be suitable for
potable water systems.
• A manual shut off valve must be installed on the cold
water inlet to the water heater between the main water
supply line and the water heater.
• Only a gate valve or a ball valve is to be used on the cold
water supply.
• No stop taps or check valves are to be used as this will
void the warranty and damage the water heater.
• Check that the cold water pressure is sufficient for the
water heater. If it is above 1000kPa an approved pressure
limiting valve must be fitted to the installation.
• Before installing the water heater, flush the water line
to remove all debris, and after installation is complete,
purge the air from the line. Failure to do so may cause
damage to the water heater.
• There is a wire mesh filter on the water heater cold inlet
to prevent debris from entering the water heater. Clean
the filter after initial installation to ensure it has not
been blocked.
hot water
outlet
cold water
intlet
Summary of Contents for KGC20BLA
Page 1: ...Gas Continuous Flow Hot Water System Installation Manual ...
Page 20: ...20 notes Kelvinator Gas Continuous Flow hot water system Notes ...
Page 21: ...Kelvinator Gas Continuous Flow hot water system notes 21 Notes ...
Page 22: ...22 notes Kelvinator Gas Continuous Flow hot water system Notes ...