Kelvinator gas continuous flow hot water systems

  troubleshooting    11

Troubleshooting

Temperature and amount of hot water

Problem

Possible solutions

It takes a long time for hot water to 
reach the fixtures. 

The time it takes to deliver hot water from the water heater to your fixtures 
depends on the length of piping between the two. The longer the distance or 
the bigger the pipes, the longer it will take to get hot water. 

The water is not hot enough

If a tempering valve is installed, is it set too low or malfunctioning?  
Are the cold water and hot water lines cross connected?
Is the gas supply valve fully open? 
Is the gas line sized properly? 
Is the gas supply pressure enough?   
Is the set temperature set too low?    
Is the combustible air inlet or exhaust outlet blocked?

The water is too hot

Is the set temperature set too high? 

The hot water is not available when a 
fixture is opened.

Does the water heater have a 240V 50Hz power supply available?
If you are using the remote controller, is the power button turned on? 
Is the gas supply valve fully open? 
Is the water supply valve fully open? 
Is the filter on cold water inlet clean? 
Is the hot water fixture sufficiently open to draw at least 3.0l/min through the 
water heater? 
Is the water heater frozen?
Is there gas available to the water heater and (if applicable) does the gas 
storage tank have enough gas in it?

The hot water gets cold and stays cold

Is the flow rate enough to keep the water heater running? 
Is the gas supply valve fully open? 
Is the filter on the cold water inlet clean? 
Are the fixtures clean of debris and obstructions? 

Fluctuation in hot water temperature.

Is the filter on the cold water inlet clean? 
Is the gas line sized properly? 
Is the supply gas pressure enough? 
Are the cold water and hot water lines cross connected?

Water heater

Problem

Possible solutions

Burner does not ignite when water 
goes through the water heater.

Is the flow rate over 3.0l/min?  
Is there a 240V 50Hz power supply available to the water heater?
Are the cold water and hot water lines cross connected or reversed?
If you use the remote controller, is the power button turned on? 

The fan motor is still spinning after 
operation has stopped. 

This is normal. After operation has stopped, the fan motor keeps running for 
15 – 75 seconds in order to re-ignite quickly, as well as push all exhaust gas 
out of the flue.  

White vapour clouds are coming from 
the hot air outlet of the water heater 

It is normal to see water vapour clouds or steam coming from the hot air outlet 
of the water heater especially during cold and wet days.

Remote controller (optional)

Problem

Possible solutions

Remote controller does not display 
anything when the power button is 
turned on. 

Press the ON/OFF button. 
If the lamp does not light:
Make sure the water heater has power supply. 
Make sure the connection to the water heater is correct.

An ERROR code is displayed

Call a service technician.

Remote  controller  can  not  change 
the set temperature.

Is priority lamp lit? If it is not, press  the priority button after closing all  
hot water taps.

Summary of Contents for KGC20BLA

Page 1: ...Gas Continuous Flow Hot Water System User Manual ...

Page 2: ... materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this hot water system please contact your local authorities and ask for the correct method of disposal Contact an authorised installer for installation of this hot water system Contact an authorised service technician for repa...

Page 3: ...u ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service This symbol indicates never to do this This symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthi...

Page 4: ...sed in water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts If this water heater is a 70 C model installed as part of a gas boosted solar hot water system please refer to the user manual supplied with that system for safety regarding the relief valves installed to limit temperature pressure and energy Ensure the following safety instruc...

Page 5: ...ing label position Serial number label position Gas type label position MODELS KGC20BNA KGC20KNA KGC20SNA KGC20BLA KGC20KLA KGC20SLA KGC26BNA KGC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Inlet Supply Pressure kPa LPG 2 61 min 2 89max 2 61 min 2 89max Water Supply Pressure kPa...

Page 6: ... only Open any hot tap or fixture in the house Open the cold water isolation valve located on the inlet to the water heater Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation valve located on the inlet to the water heater Plug in the power cord to the power outlet if...

Page 7: ... water caution The following process should be completed by the installer only Once all checks have been completed please clean filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn the tap off 3 Fully open the manual gas control valve installed ...

Page 8: ...r is off PRIORITY C BURNER ON ON OFF PRIORITY HOT COOL MADE IN JAPAN Main priority lamp priority button burner on lamp KGCMRCA ON OFF button burner on lamp display set temperature 40 NOTE If power to the hot water system is lost then re set the remote controller will also lose power and switch off If the water is still running during this time it will go cold until the remote controller is switche...

Page 9: ...nd being damaged Follow these instructions carefully 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitchen laundry room etc When the water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s...

Page 10: ...ning and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4 Open all hot water taps in the house bathroom kitchen laundry room etc When the residual water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s drain plugs Unscrew the drain plugs to drain all th...

Page 11: ...to keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is the filter on the cold water inlet clean Is the gas line sized properly Is the supply gas pressure enough Are the cold water and hot water lines cross connected Water heater Problem Possible solutio...

Page 12: ...12 notes Kelvinator gas continuous flow hot water systems Notes ...

Page 13: ...Kelvinator gas continuous flow hot water systems notes 13 Notes ...

Page 14: ...14 notes Kelvinator gas continuous flow hot water systems Notes ...

Page 15: ... is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is dam...

Page 16: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: