background image

Your gas continuous flow hot water system (please tick)

Stand alone installation

50°C –  

  20L Natural Gas KGC20BNA

  

  26L Natural Gas KGC26BNA

 

  

  20L LPG Gas KGC20BLA

  

  26L LPG Gas KGC26BLA

60°C –  

  20L Natural Gas KGC20KNA

  

  26L Natural Gas KGC26KNA

 

  

  20L LPG Gas KGC20KLA

  

  26L LPG Gas KGC26KLA

Gas boosted solar installation

70°C –  

  20L Natural Gas KGC20SNA

  

  26L Natural Gas KGC26SNA

  

  20L LPG Gas KGC20SLA

  

  26L LPG Gas KGC26SLA

Serial number:
Installation date:
Installed by:
Notes:

When calling the service centre, please refer to this section 
of the user manual as it will help you to describe your gas 
continuous flow hot water system and assist you in quoting 
its model number.

Rating label 

position 

Serial number  

label position

Gas type label 

position

MODELS

KGC20BNA 
KGC20KNA  

KGC20SNA 

KGC20BLA 
KGC20KLA 

KGC20SLA

KGC26BNA 
KGC26KNA 

KGC26SNA 

KGC26BLA 
KGC26KLA 

KGC26SLA 

Capacity L/min

20L/min

26L/min

Gas Input MJ/h

160

195 

Inlet Supply Pressure 
kPa – Nat. Gas

1.13 min.

1.13 min.

2.75 max.

2.75 max.  

Inlet Supply Pressure 
kPa - LPG

2.61 min
2.89max

2.61 min
2.89max

Water Supply 
Pressure kPa 

150* min.

150* min.

1200 max

1200 max

Height mm  

542  

542 

Depth mm  

170  

215 

Width mm  

350  

350 

Weight kg  

15.7  

17.2 

Gas Connection mm

20 BSP

20 BSP 

Water Connections

15 BSP

15 BSP 

Ignition

Electronic

Electronic 

Electrical Supply Voltage

240 AC

240 AC

Operating current

0.8A

0.8A

*The water heater will operate at reduced performance when inlet water 

supply pressures are below 340kPa.

Kelvinator gas continuous flow hot water systems  

specifications  5

Specifications

Summary of Contents for KGC20BLA

Page 1: ...Gas Continuous Flow Hot Water System User Manual ...

Page 2: ... materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this hot water system please contact your local authorities and ask for the correct method of disposal Contact an authorised installer for installation of this hot water system Contact an authorised service technician for repa...

Page 3: ...u ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service This symbol indicates never to do this This symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthi...

Page 4: ...sed in water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts If this water heater is a 70 C model installed as part of a gas boosted solar hot water system please refer to the user manual supplied with that system for safety regarding the relief valves installed to limit temperature pressure and energy Ensure the following safety instruc...

Page 5: ...ing label position Serial number label position Gas type label position MODELS KGC20BNA KGC20KNA KGC20SNA KGC20BLA KGC20KLA KGC20SLA KGC26BNA KGC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Inlet Supply Pressure kPa LPG 2 61 min 2 89max 2 61 min 2 89max Water Supply Pressure kPa...

Page 6: ... only Open any hot tap or fixture in the house Open the cold water isolation valve located on the inlet to the water heater Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation valve located on the inlet to the water heater Plug in the power cord to the power outlet if...

Page 7: ... water caution The following process should be completed by the installer only Once all checks have been completed please clean filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn the tap off 3 Fully open the manual gas control valve installed ...

Page 8: ...r is off PRIORITY C BURNER ON ON OFF PRIORITY HOT COOL MADE IN JAPAN Main priority lamp priority button burner on lamp KGCMRCA ON OFF button burner on lamp display set temperature 40 NOTE If power to the hot water system is lost then re set the remote controller will also lose power and switch off If the water is still running during this time it will go cold until the remote controller is switche...

Page 9: ...nd being damaged Follow these instructions carefully 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitchen laundry room etc When the water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s...

Page 10: ...ning and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4 Open all hot water taps in the house bathroom kitchen laundry room etc When the residual water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s drain plugs Unscrew the drain plugs to drain all th...

Page 11: ...to keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is the filter on the cold water inlet clean Is the gas line sized properly Is the supply gas pressure enough Are the cold water and hot water lines cross connected Water heater Problem Possible solutio...

Page 12: ...12 notes Kelvinator gas continuous flow hot water systems Notes ...

Page 13: ...Kelvinator gas continuous flow hot water systems notes 13 Notes ...

Page 14: ...14 notes Kelvinator gas continuous flow hot water systems Notes ...

Page 15: ... is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is dam...

Page 16: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: