Congratulations and thank you for choosing our Electric 

your new air conditioner a pleasure to use. Before you use 
the air conditioner, we recommend that you read through 
the entire user manual, which provides the description of 
the air conditioner and its functions.
To avoid the risks that are always present when you use an 
electrical appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not 
damaged. If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

environmental tip 

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this air conditioner, please contact 

your local authorities and ask for the correct method  
of disposal.

•  This product contains refrigerant which must be 

reclaimed by a licensed refrigeration mechanic before the 
product can be disposed of.

refrigerant warning

This unit uses refrigerant R32 and must be disposed of 
by a licensed refrigeration mechanic with knowledge of 
appropriate gas reclamation methods.

caution

•    The air conditioner is not intended for use by young 

children or i rmed persons without supervision.

•    Young children should be supervised to ensure that they 

do not play with the air conditioner. 

•    Contact an authorised installer for installation of this unit.
•    Contact an authorised service technician for repair or 

maintenance of this unit.

•    If the power cord is to be replaced, replaceme

nt work  

must be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with the national wiring Standards by authorised 
personnel only.

Safety precautions

 .....................................................................

 

3

Prior to operation.............................................................. 4

Unit parts identi cation

 ............................................................

 

5

Operating instructions

 ..............................................................

5

Maintenance ...................................................................... 9

Installation instructions

 ..........................................................

10

Troubleshooting

 .......................................................................

12

Conditions of use 

This appliance is designed and intended to be used in normal 
domestic applications only.

              

Congratulations

Contents

Important information that may  
impact your Manufacturer’s Warranty

Adherence to the directions for use in this manual is 
extremely important for health and safety. Failure to  
strictly adhere to the requirements in this manual may 
result in personal injury, property damage and affect  
your ability to make a claim under the Kelvinator 
manufacturer’s warranty provided with your product. 
Products must be used, installed and operated in 
accordance with this manual. You may not be able to  
claim on the Kelvinator manufacturer’s warranty in the 
event that your product fault is due to failure to adhere  
this manual.

Do not use means to accelerate defrosting or to clean, 
other than those recommended by the manufacturer.
The appliance shall not be stored in a room with 
continuously operating ignition sources. Do not pierce 
or burn.

Summary of Contents for KWH53CRF

Page 1: ...Window Wall Electronic Room Air Conditioner KWH22CRF KWH22HRF KWH27CRF KWH27HRF KWH39CRF KWH39HRF KWH53CRF KWH53HRF KWH60CRF KWH60HRF Refrigerant R32 CARE USE Australians love a Kelvinator...

Page 2: ...he air conditioner is not intended for use by young children or i rmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact...

Page 3: ...bles such as gasoline benzene thinner etc It may cause an explosion or fire Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire...

Page 4: ...the room well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use...

Page 5: ...e 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet Controls The electronic control keypad will...

Page 6: ...or light for Auto mode When you select Auto mode a beep will sound indicating this MODE option was selected Temperature settings up Press the keypad to increase the set operating temperature of the un...

Page 7: ...p is heard from the main unit when initiating program commands from the remote control to the main unit b The main unit does not respond to the remote control program commands Battery Replacement 1 Sl...

Page 8: ...the main control panel Note Note The LED display will default to show the ambient room temperature within 10 seconds of all program commands Power To turn the air conditioner power on off aim the remo...

Page 9: ...e air conditioner will stop completely When the power is restored the air conditioner will start automatically with all the previous settings preserved in the memory The treatment of condensed water 1...

Page 10: ...brick cut away to clear louvres 45 brick cut away to clear louvres Front Louvre support cannot be provided AIR IN AIR OUT 100mm minimum AIR IN OPTION A BRICK WALL AIR OUT A 100mm 100mm IR IN AIR IN T...

Page 11: ...he slots See Fig 2 Step 2 Remove the frame 1 Remov xing screws from the frame See Fig 3 Screws can be in different positions of the frame for different models usually there are 2 screws at the rear of...

Page 12: ...cuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When po...