WIRING DIAGRAM - 4HR, 4HC / 8HR, 8HC
E4HR, E4HC / E8HR, E8HC
E4HR2, E4HC2 / E8HR2, E8HC2
22
PRINCIPLES OF OPERATION
WIRE DIAGRAM
00-C-2030-00 F
YELLOW
BLUE
BLUE
WHITE
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
WHITE
BLUE
BLUE
WHITE
RED (EXTRA)
BLACK
BLACK
BLACK
BLUE
WHITE
BLACK
WHITE
BLACK
BLACK
BLK.
BLK.
6
5
4
3
2
1
S
S
LAMP
BALLAST
RUN CAP.
TERMINAL
115 VAC. 60 Hz.-10
LIGHT
TEMP.
COMPRESSOR
FAN MOTOR
LAMP
BALLAST
BOARD
SWITCH
CONTROL
POWER SUPPLY
RUN CAP.
LAMP
BALLAST
CONTROL
SWITCH
TEMP.
LIGHT
S
PROTECTOR
MOTOR
FAN MOTOR
S
C
R
COMPRESSOR
BLACK
W
HITE
TERMINAL BOX
1
2
3
MOTOR PROTECTOR
(PTCR)
(PTCR)
4
START CAP.
START CAP.
3
2
1
4
POWER SUPPLY
115 VAC. 60 Hz.-10
-THE 8HF/4HJ/8HJ HAVE NO LIGH
TS.
NOTES: -RED WIRE IS AN EXTRA WIRE.
(BLUE)
(L2)
N
(BROWN)
SWITCH
SUPPLY
L1
S
BALLAST
LAMP
-THE 4HR AND 4HC HAS ONLY ONE
LIGHT.
ELB
FUSE
GFCI
FUSE
(SOME MODELS)
(SOME MODELS)
ELECTRICAL INFORMATION.
220 VAC. 50 Hz.-10
SEE SERIAL PLATE FOR
EXPORT MODELS ONLY
POWER SUPPLY FOR
220 VAC. 60 Hz.-10
SWITCH
SUPPLY
( SEE NOTES)
OR
Dipping Cabinet 1298.02 2/3/03 1:14 PM Page 24
Summary of Contents for R-404A
Page 3: ...Introduction...
Page 13: ...SECTION II Principles of Operation...
Page 14: ......
Page 28: ......
Page 29: ...SECTION III Maintenance Repair...
Page 55: ...PARTS LISTING With Illustration Identification...
Page 56: ...CABINET PARTS EXPLODED VIEW 54 CABINET PARTS EXPLODED VIEW 2 1 3 4 7 9 8 6 10 11 5...
Page 60: ...CONDENSING UNIT EXPLODED VIEW 58 CONDENSING UNIT EXPLODED VIEW...
Page 62: ...ELECTRICAL PARTS EXPLODED VIEW 60 ELECTRICAL PARTS EXPLODED VIEW...
Page 64: ...1 6 7 2 4 3 5 LID EXPLODED VIEW 62 LID EXPLODED VIEW...
Page 66: ......
Page 67: ...ACCESSORIES...
Page 68: ......
Page 73: ...ADJUSTABLE LEG KIT 52 1831 01 ACCESSORIES 71...
Page 74: ...CASTER KIT 52 1830 01 72 ACCESSORIES...
Page 76: ...CAN CLAMP INSTALLATION 74 ACCESSORIES...
Page 79: ......
Page 80: ...by National Refrigeration Products 563 Corbin Road Honea Path South Carolina 800 486 8369...