METERING DEVICE/HEAT EXCHANGER REPLACEMENT
46
MAINTENANCE & REPAIR
1. Disconnect power to the cabinet.
2. Pull out the condensing unit.
3. Disconnect the liquid line.
4. Disconnect the suction line at the compressor.
5. Cut off the evaporator inlet tube about five
inches down below the point where it comes out
of the cabinet.
6. Remove the capillary tube from the inside of the
evaporator inlet tube.
7. Connect the end of the capillary on the new heat
exchanger to the evaporator inlet tube.
8. Connect the suction line to the compressor valve
and the capillary line to the bottom of the drier.
Replace the drier.
9. Evacuate and recharge.
10. Secure short lengths of insulating tubing provided
around exposed tubing in place with tape and
seal to bottom of the cabinet with permagum
which is provided.
11. Reconnect power to the cabinet.
Dipping Cabinet 1298.02 2/3/03 1:15 PM Page 48
Summary of Contents for R-404A
Page 3: ...Introduction...
Page 13: ...SECTION II Principles of Operation...
Page 14: ......
Page 28: ......
Page 29: ...SECTION III Maintenance Repair...
Page 55: ...PARTS LISTING With Illustration Identification...
Page 56: ...CABINET PARTS EXPLODED VIEW 54 CABINET PARTS EXPLODED VIEW 2 1 3 4 7 9 8 6 10 11 5...
Page 60: ...CONDENSING UNIT EXPLODED VIEW 58 CONDENSING UNIT EXPLODED VIEW...
Page 62: ...ELECTRICAL PARTS EXPLODED VIEW 60 ELECTRICAL PARTS EXPLODED VIEW...
Page 64: ...1 6 7 2 4 3 5 LID EXPLODED VIEW 62 LID EXPLODED VIEW...
Page 66: ......
Page 67: ...ACCESSORIES...
Page 68: ......
Page 73: ...ADJUSTABLE LEG KIT 52 1831 01 ACCESSORIES 71...
Page 74: ...CASTER KIT 52 1830 01 72 ACCESSORIES...
Page 76: ...CAN CLAMP INSTALLATION 74 ACCESSORIES...
Page 79: ......
Page 80: ...by National Refrigeration Products 563 Corbin Road Honea Path South Carolina 800 486 8369...