Commissioning Procedure
Installed correctly the burner should not emit any
fumes into the room. The following procedure should
be undertaken to test that the unit is operating
correctly.
1 After unit has been operating for a short period a
smoke match, smoke tube, carbon dioxide analyser or
similar should be directed at the top opening of the
unit.
2 This procedure should be undertaken with the
following conditions in the room:
• Open or closed windows
• Operation of extraction/exhaust fans, range
hoods etc
• Operation of other gas appliances
• Operation of optional appliance fan at any speed.
3 Should any spillage be detected the cause must be
rectified before allowing commissioning of unit.
User Instructions
1. WARNING NOTE: Properly installed and operated
this appliance will not leak gases. Persistent fume emission
must not be tolerated. If fume emission does exist, then
the following immediate action should be taken.
A Open doors and windows to ventilate room.
B Turn the fire off.
C Check for flue blockage and clear if necessary.
D Do not attempt to relight the burner until the cause
of the emission has been identified and rectified. Should
assistance be required contact nearest agent.
E The gas burner is designed to work in a Kemlan
Horizon electronic power flue ignition system. Working
correctly there will be no spillage. Unit should cut out
if not enough draw to ensure proper functioning.
2 Initially the Kemlan coal fire may burn with a slightly
blue flame. After approximately 20 minutes the fire will
settle down and burn with a yellow flame.
3 As with all gas fires your gas coal/pebble or log fire
should be regularly serviced. We recommend once
each year. Contact your for an authorized person to
follow has been set out in attached leaflet.
4 PLEASE NOTE: Only logs provided by Kemlan
should be used with this appliance.
5 DO NOT place articles on or against this appliance.
DO NOT use or store flammable materials near
this appliance.
DO NOT spray aerosols in the vicinity of this
appliance whilst it is in operation.
Primarily a decorative appliance not certified as a
space heater.
6 The appliance is a live fuel effect product designed
to operate with luminous flames and may exhibit slight
carbon deposition.
Warranty
Provided the appliance has been correctly installed
according to instructions, Kemlan guarantee the cost of
replacing parts and the labour in connection therewith
for a period of 12 months from the date of installation.
Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces
For further information contact Kemlan Australia
Head Office: 59 Pineapple St Zillmere QLD 4034 Telephone 07 3263 8488 Facsimile 07 3263 6452 www.kemlan.com