Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces

Measurement and Specifications of Fan Power Flue

INTERNAL FAN

SINGLE SIDED - REAR EXIT 

INTERNAL FAN

EXTERNAL FAN

DOUBLE SIDED - SIDE EXIT 

CANTILEVER - REAR EXIT

H

1210

1210

1210

H

H

1010

1010

1010

H

Summary of Contents for 1100 Cantilever

Page 1: ......

Page 2: ...l Type 2 Power Flue Decorative Gas Fireplace DATA PLATE Refer to data plate for information in respect to gas pressure consumption and gas type Natural or LPG Data Plate is located under the gas burner and is accessed by lifting front access panel or removing base plate Location Requirements Power flue systems utilise a fan assisted draft to ensure products of combustion are exited through a flue ...

Page 3: ...to 50 MJ h input 300 Appliances over 50 MJ h input 500 b From the ground or above a balcony 300 c From a return wall or external corner 500 d From a gas meter M 1000 e From an electricity meter or fuse box P 500 f From a drain or soil pipe 150 g Horizontally from any building structure unless appliance approved for closer installation or obstruction facing a terminal 500 h From any other flue term...

Page 4: ...d by a licensed gas fitter It is the responsibility of the gas fitter to follow the regulations set out in the Gas Code that dictate the procedures to follow when installing a gas appliance particularly regarding gas pipe sizing and checking of pressures see page 10 Installation 1 Access must always be available to the fan system for servicing If installing the internal fan system an access panel ...

Page 5: ...ons Kemlan Power Flue Horizon Gas Fireplaces Measurement and Specifications of Fan Power Flue INTERNAL FAN SINGLE SIDED REAR EXIT INTERNAL FAN EXTERNAL FAN DOUBLE SIDED SIDE EXIT CANTILEVER REAR EXIT H 1210 1210 1210 H H 1010 1010 1010 H ...

Page 6: ...n Instructions Kemlan Power Flue Horizon Gas Fireplaces Framing Dimensions DOUBLE SIDED SINGLE SIDED OUTSIDE WALL OUTER FLUE ACTIVE FLUE REDUCER FAN MOTOR FAN HOUSING FLASHING COVER CEILING ROOFING MATERIAL FLASHING COVER FAN HOUSING SCALE 1 20 SCALE 1 20 SCALE 1 7 MAX HEIGHT BASED ON 2 4M CEILING ...

Page 7: ...uctions Kemlan Power Flue Horizon Gas Fireplaces Section of Fan Power Flue INTERNAL FAN SIDE EXIT EXTERNAL FAN SIDE EXIT SINGLE SIDED ELEVATION MAX HEIGHT 22OMM BASED ON 2 4M CEILING CANTILEVER ELEVATION MAX HEIGHT 300MM BASED ON 2 4M CEILING Elevation of Fan Power Flue ...

Page 8: ... burner will then ignite from pilot Burner is turned off by turning off wall switch Power flue system does not have a high low switch burner switch Laying the fire Coal Pebble Evenly spread a bag of Vermiculite into the burner tray Tray should be completely filled to the top with Vermiculite to a depth of approximately 45mm Unpack the coals pebbles contained in a clear plastic bag and lay a row of...

Page 9: ...es Laying the fire Coal Pebble MARK 2 COALS 440 500 390 X 240 MARK 2 COALS 600 460 X 260 MARK 2 COALS 700 580 X 260 MARK 2 PEBBLES 700 580 X 260 MARK 2 COALS 700 800 600 X 155 MARK 2 PEBBLES 700 800 600 X 155 MARK 2 COALS 1000 992 X 155 MARK 2 PEBBLES 1000 922 X 135 ...

Page 10: ...les on the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Log NO 6 10 9 and...

Page 11: ...laced on the rear log in the centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear log in the position where the log reduces in height The charred end is located on the front log 3 with the charred effect facing toward the right hand side 4 LOCATE LOG NO 4 Place it on the left side of the re...

Page 12: ...front log no s 2 and 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the fire L O G S P O S I T I O N I N G O F A L L L O G S It is important to follow the log recommended positioning Not doing so can adversely effect the operation of the appliance This diagram sho...

Page 13: ...to the large rear log no 1 6 LOCATE LOG NO 7 The charred effect of the log is positioned on the smaller coal in the centre of the burner on the right hand side The right hand side of the log is positioned between the front metal upright on the side 4 LOCATE LOG NO 4 This log is placed with the thinner edge on the smaller coal The charred effect is facing towards the front of the burner The whole l...

Page 14: ...n Horizon electronic power flue ignition system Working correctly there will be no spillage Unit should cut out if not enough draw to ensure proper functioning 2 Initially the Kemlan coal fire may burn with a slightly blue flame After approximately 20 minutes the fire will settle down and burn with a yellow flame 3 As with all gas fires your gas coal pebble or log fire should be regularly serviced...

Page 15: ...Notes For further information contact Kemlan Australia Head Office 59 Pineapple St Zillmere QLD 4034 Telephone 07 3263 8488 Facsimile 07 3263 6452 www kemlan com ...