Commissioning Procedure

Installed correctly the burner should not emit any
fumes into the room. The following procedure should
be undertaken to test that the unit is operating
correctly.

1 After unit has been operating for a short period a
smoke match, smoke tube, carbon dioxide analyser or
similar should be directed at the top opening of the
unit.

2 This procedure should be undertaken with the
following conditions in the room:

• Open or closed windows
• Operation of extraction/exhaust fans, range 
hoods etc
• Operation of other gas appliances
• Operation of optional appliance fan at any speed.

3  Should any spillage be detected the cause must be
rectified before allowing commissioning of unit.

User Instructions

1.  WARNING NOTE: Properly installed and operated
this appliance will not leak gases. Persistent fume emission
must not be tolerated. If fume emission does exist, then
the following immediate action should be taken.

A Open doors and windows to ventilate room.

B Turn the fire off.

C Check for flue blockage and clear if necessary.

D Do not attempt to relight the burner until the cause
of the emission has been identified and rectified. Should
assistance be required contact nearest agent. 

E The gas burner is designed to work in a Kemlan
Horizon electronic power flue ignition system. Working
correctly there will be no spillage. Unit should cut out
if not enough draw to ensure proper functioning.

2 Initially the Kemlan coal fire may burn with a slightly
blue flame. After approximately 20 minutes the fire will
settle down and burn with a yellow flame.

3 As with all gas fires your gas coal/pebble or log fire
should be regularly serviced. We recommend once
each year. Service information for an authorised person
to follow has been set out in attached leaflet.

4 PLEASE NOTE: Only logs provided by Kemlan
should be used with this appliance.

5 DO NOT place articles on or against this appliance. 

DO NOT use or store flammable materials near 
this appliance. 

DO NOT spray aerosols in the vicinity of this 
appliance whilst it is in operation. 

Primarily a decorative appliance not certified as a 
space heater.

6 The appliance is a live fuel effect product designed
to operate with luminous flames and may exhibit slight
carbon deposition.

7. The guard is fitted to this appliance to reduce the
risk of fire or injury from burns and no part of it should
be permanently removed.

SERVICE - WARNING: ONLY TO BE SERVICED BY
AN AUTHORISED  PERSON

Warranty

Provided the appliance has been correctly installed
according to instructions, Kemlan guarantee the cost of
replacing parts and the labour in connection therewith
for a period of 12 months from the date of installation. 

Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces

Summary of Contents for Horizon Natural Draft Electronic Ignition

Page 1: ...Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces...

Page 2: ...Ignition Gas Fireplace DATA PLATE Refer to data plate for information in respect to gas pressure consumption and gas type Natural or LPG Data Plate is located under the gas burner and is accessed by...

Page 3: ...pellet Kemlan recommends that all gas fires be serviced every year All gas units must be fitted by a licensed gas fitter It is the responsibility of the gas fitter to follow the regulations set out i...

Page 4: ...CONNECTION UNDER BURNER Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Measurement and Specifications of N D E I SINGLE SIDED CANTILEVER DOUBLE SIDED UNDER BURNER U...

Page 5: ...5 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Framing Dimensions DOUBLE SIDED SINGLE SIDED B INCLUDE 10MM PLASTERBOARD...

Page 6: ...6 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Section SINGLE SIDED ELEVATION CANTILEVER ELEVATION SINGLE SIDED SECTION CANTILEVER SECTION Elevation...

Page 7: ...pilot and main burner will then ignite from pilot Burner is turned off by turning off wall switch System does not have a high low burner switch Laying the fire Coal Pebble Evenly spread a bag of Vermi...

Page 8: ...ireplaces Laying the fire Coal Pebble MARK 2 COALS 440 500 390 X 240 MARK 2 COALS 600 460 X 260 MARK 2 COALS 700 580 X 260 MARK 2 PEBBLES 700 580 X 260 MARK 2 COALS 700 800 600 X 155 MARK 2 PEBBLES 70...

Page 9: ...s two holes on the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover t...

Page 10: ...log is placed on the rear log in the centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear l...

Page 11: ...og no s 2 and 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the...

Page 12: ...large rear log no 1 6 LOCATE LOG NO 7 The charred effect of the log is positioned on the smaller coal in the centre of the burner on the right hand side The right hand side of the log is positioned be...

Page 13: ...e ignition system Working correctly there will be no spillage Unit should cut out if not enough draw to ensure proper functioning 2 Initially the Kemlan coal fire may burn with a slightly blue flame A...