TECHNICAL SPECIFICATIONS

*As per Clause 3.3.3 of AS/NZS 2918 for floor protector 

construction requirements.

Where a sample appliance installation (or prototype 

installation) has not been tested, the floor protector 

shall extend either to a distance of not less than 500mm 

(measurement 

C

) beyond any part of the appliance or a 

lesser distance at which it forms a abutment with a wall or 

heat shield (subject to the requirements of Clause 3.2).

Heating capacity of this appliance is given as a guide only 

and may vary depending on the climate zone and type 

of dwelling (floor plan and degree of insulation).  Consult 

your local authorised distributor to determine realistic 

expectations for your home.

Heat output and fuel consumption of this appliance 

is dependent on the moisture content, size, loading 

geometry and the type of hardwood used.

The appliance complies to the safety standards AS/NZS 

2918.  When in use some parts may become hot.  A 

suitable fireguard is recommended where the very young, 

elderly or infirm are concerned.

CONSTRUCTION

- 6 & 8mm heavy duty steel firebox – fully welded

- 25mm thick firebrick lined floor

- 19mm ceramic lined sides and baffle

PERFORMANCE

 

- Heating capacity – 220-320m2 (23-33 squares)

- Peak heat output – 21.6kW

- Average output – 2.0g/kg

- Average efficiency – 61%

Glass viewing area

 

- 602mm wide x 302mm high

Flue pipe

 

      

- ø150mm – top exit

Shipping weight

 

- 215kg

All dimensions shown are approximate.  Check all 

dimensions accurately before installation.  Before 

installing refer to the installation instructions.  

In line with our policy of continuous improvement, we 

reserve the right to alter specifications without notice.

A - 

100mm

B - 

550mm

C - 

150mm

D - 

3200mm

E - 

945mm

F - 

620mm

G - 

1200mm

H - 

1060mm

I* - 

500mm

STANDARD INSTALLATION

MINIMUM CLEARANCES FOR THE KEMLAN XL SOLID FUEL 

APPLIANCE INSTALLED WITH A DEFAULT FLUE KIT

CORNER INSTALLATION

I*

I*

NOTE:

The floor protector consists of a 12mm thick cement fibre sheet 

which has a thermal resistance of 0.8² k/W, per 4mm thick sheet

A

C

C

F

F

H

D

G

B

E

Summary of Contents for XL

Page 1: ...TIONS WITH THE UNIT ON COMPLETION 1x900mm LENGTH HEATSHIELD OR DECROSHIELD MUST BE FITTED TO THE FLUE TO ACHIEVE CLEARANCES TO HEAT SENSITIVE MATERIALS 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty Other parts are covered by one year limited warranty Head Office Telephone Facsimile Website Business hours Email 13 French Avenue Brendale Queensland 4500 07 3263 8448 07 3263 6...

Page 2: ... When in use some parts may become hot A suitable fireguard is recommended where the very young elderly or infirm are concerned CONSTRUCTION 6 8mm heavy duty steel firebox fully welded 25mm thick firebrick lined floor 19mm ceramic lined sides and baffle PERFORMANCE Heating capacity 220 320m2 23 33 squares Peak heat output 21 6kW Average output 2 0g kg Average efficiency 61 Glass viewing area 602mm...

Page 3: ...l flues should be trimmed level Pop rivet or screw brackets to the outside of the outer casing A FLAT CEILING A Outer casing may be painted without priming Run a bead of silicon down seam of outer casing to ensure against leaks All casing flue pipes must be connected via pop rivets supplied by installer Stainless steel flue pipe All flue pipes must be connected via pop rivets supplied by installer...

Page 4: ...cket supplied 1000mm minimum distance above roof line Outer casing may be painted without priming Run a bead of silicon down seam of outer casing to ensure against leaks All casing flue pipes must be connected via pop rivets supplied by installer Stainless steel flue pipe All flue pipes must be connected via pop rivets supplied by installer 10 8 6 Roof flashing supplied by contractor NOTE When dec...

Page 5: ...LOW MEDIUM LOW 3000 3000 3000 3000 or less 3000 or less 1000 min if clear within 3000 of top of flue Increase from 1000 min until clear within 3000 of top of flue More than 3000 More than 3000 600 min 600 min Any nearby structure Increase as necessary until nothing within 3000 of flue top INSTALLATION INSTRUCTIONS MINIMUM HEIGHT OF FLUE SYSTEM EXIT INSTALLATION TO COMPLY WITH AS NZS 2918 ...

Page 6: ...6 CERTIFICATE GOES HERE ...

Page 7: ...Don t touch the surface It will be soft and gummy during this paint curing phase Once cured it will not be soft again CURE WITH 3 FIRES Most stoves cure with 3 burns The first two 2 should be 250 F for 20 minutes or about half a normal fire Let the stove cool down between burns The last fire should be 500 F to 700 F for at least 45 minutes The point being cure slowly without a hot fire Stoves with...

Page 8: ...en it may be returned to its desired setting 6 To set the fire for overnight burn two thirds fill the firebox with hardwood and fully open the air inlet Once the fire is burning well the air inlet control should be shut down approximately three quarters of its travel Setting the air inlet control may be varied to suit your particular requirements and the quality and size of your firewood Remember ...

Page 9: ...higher heat production than wet or green wood The difference between the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green hardwood Green white ash for instance is not as good a fuel as dry tamarack The reason for the superiority of dry wood is easy to understand Heat cannot be produced until moisture has been driven ...

Page 10: ...e heater or re installation of replacement heater 5 CLAIMS 5 1 i Kemlan will provide a full replacement of the heater in the first five years after installation ii Replacement in the subsequent five years i e sixth to tenth year after installation will be on the following basis Owner will pay twenty percent of purchase price if the claim is made in the sixth year and a further ten percent per year...

Reviews: