Lubrication and Maintenance
KM00321,00002CB -19-03MAY10-1/1
KM00321,000017D -19-16MAY12-1/1
KM00321,00001ED -19-11AUG09-1/1
Grease
Use grease based on NLGI consistency numbers and the
expected air temperature range during the service interval.
AVIA AVIALITH 2 EP grease is recommended.
Other greases may be used if they meet the following
specification:
NLGI Service Classification GC-LB
IMPORTANT: Some types of grease thickeners are
not compatible with others. Contact your
lubricant supplier before mixing various
types of lubricants.
KM1000899
—UN—09JUN09
Every 10 Hours - Hook and Locking Devices
Clean hook (A) and locking devices (B).
Apply a coat of grease to hook (A) and locking devices
(B) using a brush.
A—Hook
B—Locking Devices
KM1000945
—UN—1
1AUG09
Every 50 Hours - Wheel Nuts
Retighten wheel nuts.
Specification
Wheel nuts—Torque.....................................................................350 Nm
258 lb-ft
KM1000943
—UN—1
1AUG09
45-2
031318
PN=32