Lubrication and Periodic Service
KM00321,0000BA9 -19-06MAY21-5/5
Continued on next page
KM00321,0000A9C -19-15MAY20-1/5
5. Attach thread sealing tape to the drain screw (A).
6. Remove the oil hand pump and then reinstall drain
screw (A) immediately to prevent oil loss.
7. Tighten drain screw (A) to specification.
Specification
Drain screw—Torque..................................................... 10 N·m (7.4 lb-ft)
8. Reinstall the rotor (see Install Rigid StalkBuster™
Rotors or Install Articulated StalkBuster™ Rotors
(Option) in Service Section).
A—Drain Screw
KM506470
—UN—14APR21
KM504743
—UN—14APR21
StalkBuster is a trademark of Deere & Company
Every 10 Hours—Check and Clean
IMPORTANT: The daily removal of crop residues
is essential for the proper function of the
rotary harvesting unit.
Check and clean the following areas every 10 hours or
more often if necessary:
1. Check and clean the area between blade rotors and
gathering drum gearboxes.
KM409025
—UN—27MAR20
60-11
061721