7.2.1
Changing the filter
–
Safety instructions
The life of the filter inserts depends on the type and amount of deposited
particles.
As the dust accumulation in the filter increases, its flow resistance
increases and the extraction capacity of the product decreases.
Even in the case of products with an automatic filter cleaning system (if
present), deposits can reduce the flow resistance.
A filter change is required.
WARNING
Health hazards caused by welding fume particles
Inhalation of welding fume particles, especially welding fume particles
from welding processes on alloyed steels, can damage your health as
they are ‘respirable’. Skin contact with welding fume particles can
cause
skin irritation in sensitive individuals.
To avoid contact with and inhalation of these dust particles, wear
disposable overalls, protective goggles, gloves and a suitable Class FFP2
respiratory protection filter mask in accordance with EN 149.
WARNING
Cleaning the filter inserts is not permitted. This inevitably leads to
damage to the filter element, meaning the filter ceases to function and
hazardous substances enter the air.
During the work described in the following section, pay particular
attention to the seal on the main filter. Only an undamaged seal allows
the product to achieve a high filter efficiency. Main filters with a damaged
seal must therefore be replaced every time.
Summary of Contents for 60 650 100
Page 2: ...Typenschild einkleben ...
Page 13: ...DE 1502763 02 13 Abb 1 Unsachgemäße Positionierung der Absaugarme ...
Page 89: ...FR 1502763 02 89 Fig 19 positionnement incorrect des bras d aspiration ...
Page 128: ...NL 1502763 02 128 Afb 28 Onjuiste positionering van de afzuigarmen ...
Page 167: ...ES 1502763 02 167 Fig 37 Posicionamiento indebido de los brazos de aspiración ...
Page 206: ...PT 1502763 02 206 Fig 46 Posicionamento incorreto dos braços de aspiração ...
Page 245: ...IT 1502763 02 245 Fig 55 Posizionamento non corretto dei bracci di aspirazione ...
Page 321: ...PL 1502763 02 321 Rys 73 Nieprawidłowe ustawienie ramion odciągowych ...
Page 464: ......