B) Specification
•
For outdoor use only.
•
Uses propane or butane gas only.
•
Max wattage: 12,0 kW
•
Min. wattage: 5,0 kW
•
Consumption: 450 g/hr – 870 g/hr
•
Weight: stainless steel model G.W. 19 Kg
Powder coating model G.W. 20 Kg
•
Height: 226,5 cm
•
With
certificate
•
Articles of category I3+
C) Table of opening
ASSEMBLY PARTS
Tools needed
•
Open end wrench 10 & 13 mm
•
Adjustable opening wrench 8” long
•
Slip joint pliers 9” long.
•
Philips screwdriver w/medium blade
•
Spray bottle of soap solution for leakage test.
Parts supplied
•
Stand
(B)
with LPG tank housing
(C)
•
Assembly post
(D)
with 3 pcs post brackets
(E)
•
10 mm x 86 cm galvanized steel pipe
(F)
•
Complete burner
(G)
•
6 pcs bolts M8x16 mm
(A – 1)
for assembly post brackets and stand
•
6 pcs bolts M6x35 mm
(A – 2)
and 6 pcs nuts M6
(A – 3)
for assembly post and post brackets.
•
3 pcs pins for burner
(A – 4)
•
Reflector
(H)
81 cm with 9 pcs screws, 9 nuts and 9 washers for the reflector’s assembly end 9 pcs
washers
Φ
8
(A – 5)
and 3 pcs castle nuts
(A – 7)
for assembly the reflector on the burner.
•
0,5 m flexible hose
(I).
The flexible hose can be with fitted connection
(I
1
)
or without fitted connection
(I
2
).
•
4 pcs bolts M6x10 mm
(A – 6)
for assembly post and burner.
•
3 pcs ground fixer
(A – 9)
•
6 pcs bolts M6x10 mm (
A – 6)
, 6 pcs nuts M6
(A – 3)
e 6 pcs washers
(A – 8)
for assembly the
ground fixers on the stand.
•
Hose connector
(A – 10)
to be used
with flexible hose without connection fitted.
•
Pressure regulator with threaded output
(L
1
)
for connected hose or pressure regulator with outlet
hose connector
(L
2
)
for hose without fitted connection.
GAS PRESSURE
(mbar)
MAIN
OPENING
OPENING OF
PILOT BURNER
28/30 – 37
1,8 mm
0,18 mm
Summary of Contents for 6541090