- 77 -
Display
Description 1
Description 2
Setting
value
DEL
Delay
Automatic start/stop run-on
time
Yes
OPH
Operating hours
Operating hours
HUS
Hours Until Service Hours until maintenance
dP
delta P
Differential pressure of the filter
(kPA)
dPA
Delta P Airflow
Pressure of the extraction
volume measurement (kPA)
tP
torch Pressure
Extraction pipe vacuum (kPA)
CLE
Cleaning processes Number of cleaning processes
rEg
regulation
Extraction volume control is
active
US
1 = US, = 0
Displayed units; Metric or US
FR
Frequency
Motor frequency/motor speed
Cur
Current
Motor current
P
Power
Motor power
CH
⁰C Housing
Temperature of the side
channel compressor inside the
product
CC
⁰C CPU
Temperature control
Li
Limit
Set extraction volume limitation
(optional, only possible with
activated regulation)
Yes
SFC
Cleaning
1 = cleaning start
0 = cleaning stop
Yes
SEC
Service code
Service codes
Yes
Tab. 24: Menu
6.2.2
Setting the extraction capacity regulation
Automatic extraction capacity regulation is not active
With the standard product, the automatic extraction capacity regulation is
deactivated from the factory. If the extraction capacity drops, e.g. when the
filter is saturated, the extraction capacity must be corrected manually at
the rotary switch. When the rotary switch is turned, the target extraction
capacity appears for one second, then the actual extraction capacity
appears.