4.
OperaTiOn disTurbanCes
4.1
The mOsT usual OperaTiOn disTurbanCes are as FOllOWs
arc is not ignited:
• Cable is loose or there is a bad connection.
• Electrode of torch is highly oxidized (grey). Sharpen again lengthwise. Check that post
gas time is long enough. Check ignition by using pre-gas e.g. by 4-function operation of
torch.
• There are impurities in shielding gas (moisture, air).
• Protective hose or another insulation of torch is broken and ignition spark is “escaping”
from elsewhere than from electrode of torch.
• Torch is wet.
• At low current is used too big or blunt electrode.
gas shielding is bad (weld pool “is boiling”, electrode will be oxidized)
• There are impurities in shielding gas (moisture, air).
• There are impurities in base material (rust, base coat, grease).
• On gas nozzle or housing of tightening bushing has stuck “spatter”.
• Net of gas lens is damaged.
• There is too much draught at welding place.
• Note! With gas lens equipment you get a more balanced gas flow than with normal gas
nozzle equipment.
5.
Ordering numbers
4 m
8 m
16 m
TTK 130
627063004
627063008
627063016
TTK 130F
627063104
627063108
627063116
TTK 160
627066004
627066008
627066016
TTK 160S
627066204
627066208
627066216
TTK 220
627072004
627072008
627072016
TTK 220S
627072304
627072308
627072316
TTK 300W
627080504
627080508
627080516
TTK 350W
627085504
627085508
627085516
TTK 250WS
627075704
627075708
627075716
8