EN
4.
CONTROLLING WELDING FUNCTIONS
1
2
3
4
6
5
8
9
1
2
3
4
7
6
5
8
9
10
WIRE INCH
MANUAL
AUTOMATIC
个别
一元化
In the HF control panel you can adjust the welding current and welding voltage (V). The
functions of these adjustments depend on whether you are using the power source in
automatic or basic operating mode.
With the Wire inch button you can feed the filler wire into the welding gun.
4.1 Control panel functions in basic operation
If you are using the power source in basic operating mode without automatic functions, the
control knobs have the following functions:
With the amperage knob (A)
you can adjust the welding current and the wire feed speed.
The wire feed speed increases with the amperage level.
With the voltage knob (V)
you can adjust the welding voltage level. The voltage level
determines the arc length.
4.2 Control panel functions in automatic operation
If you are using the power source in automatic operating mode, the power source takes care
of adjusting the wire feed speed and the welding voltage according to the welding power you
adjust.
In automatic operating mode the control knobs have the following functions:
With the amperage knob (A)
you can set the welding power. The welding current, wire feed
speed and the welding voltage are adjusted automatically according to this setting.
With the voltage knob (V)
you can make fine adjustments to the welding voltage. The
middle position of the knob is the default value.
9
© Kemppi Oy / 1217
Summary of Contents for 6300110
Page 1: ...Operating manual EN ZH HF 10E 10P...
Page 2: ......
Page 3: ...OPERATING MANUAL English...