33
Troubleshooting
If air supply flow suddenly decrease or increase and user is located in a contaminated area
It is necessary to leave workplace immediately and check following:
•
Unit is assembled correctly
•
Filter condition in FA Pressure Conditioner is in good condition
•
Air hose is not damaged during use
•
Noise damper in FA Pressure FC is not clogged
•
Seal on safety hood is in good condition
Fault
Probable cause
Recommendation
The unit does not work at all.
Compressed air supply
failure.
Check the compressed air
source.
Hose damage.
Check that connecting hoses
are not damaged.
The unit does not supply the
sufficient amount of air.
Air hose or air channel
blocked.
Check and remove the
possible obstacle.
Air escapes through
leakages.
Check all sealing elements
and connections, check that
the hose is not damaged and
without leaks.
The baffle is clogged.
Replace the baffle in FA
Pressure Flow Control.
The filter in FA Pressure
Conditioner is clogged.
Replace the filter.