2
Technical data
The device may be repaired only by a person legally authorized
perform electric work!
Connection voltage, 1~ 50/60 Hz
230 V ± 15%
Loadability TIG
40% ED
230 A / 19,2 V (5,7 kVA)
60% ED
200 A / 18,0 V (4,8 kVA)
100% ED
170 A / 16,8 V (3,9 kVA)
Loadability MMA
40% ED
180 A / 27,2 V (6,0 kVA)
60% ED
150 A / 26,0 V (4,8 kVA)
100% ED
120 A / 24,8 V (3,7 kVA)
Supply cable / fuse
2,5 mm² S - 3,3 m / 16 A slow
Adjustment range
TIG
3 A (AC 5 A) / 10,0 V…230 A / 19,2 V
MMA
10 A / 20,4 V…180 A / 27,2 V
Maximum welding voltage
32 V / 180 A
OCV
50 V
Efficiency
0,8
Power factor
0,99
Open circuit power
TIG
6 W
MMA
180 W
Degree of protection
IP 23C
Measures
Length
500 mm
Width
180 mm
Height
260 mm
Weight
15 kg
8 kVA generator can provide maximum output power for the power source however
recommended generator size is 10 kVA
Summary of Contents for MasterTig MLS 2300 ACDC
Page 1: ...1 Service manual Mastertig MLS 2300 ACDC Version 1 3 1...
Page 11: ...11 Construction Z004 A004 A002 A001 Z002 Z001 behind the isolator Z003 A003 T001 T002 L001...
Page 12: ...12 Main circuit diagram...
Page 15: ...15 Main circuit card Z001 Connectors X8 X2 X8 Z004 X1 X7 X6 X5 X4 X3 X4 A001...
Page 19: ...19 Secondary rectifier Z002 Connectors X6 X5 X2 X1 X4 X3 X10 X9 X8 X7 X11...
Page 35: ...35 Notes...