6
Setup functions
Contact ignition current *
B1
20
Factory setting 20 A
3…2
30
Adjustment range 3…230 A
Spark ignition duration *
B2
1.0
Factory setting 1,0 s.
0.2
…2.
0
Adjustment range 0,2…2,0 s.
Downslope cutoff level *
B3
10
Factory setting 10 % of the welding current
5…4
0
Adjustment range 5…40 % of the welding
current
Factory settings recall *
B5
OFF
Factory setting
PAN
Recalls factory settings to the panel, but keeps
memory channels
ALL
Recalls factory settings and empties the memory
channels
Downslope interruption – upslope
angle *
B6
1
Upslope speed maximum
2
According to the upslope setting
3
According to the downslope
Non-linear downslope
(Current drop in the beginning of
downslope)
B7
OFF
Factory setting
0…5
0
Adjustment range 0…50 % of welding current
Torch switch long press *
B8
0.4
Factory setting 0,4 s.
0.3
…1.
0
Adjustment range 0,3…1,0 s.
Cooling unit post running time *
B9
OFF
Factory setting 4 min.
ON
Post-running time 30 s.
* Setting is always on ** Adjustable also by the Quick Setup
Summary of Contents for MasterTig MLS 2300 ACDC
Page 1: ...1 Service manual Mastertig MLS 2300 ACDC Version 1 3 1...
Page 11: ...11 Construction Z004 A004 A002 A001 Z002 Z001 behind the isolator Z003 A003 T001 T002 L001...
Page 12: ...12 Main circuit diagram...
Page 15: ...15 Main circuit card Z001 Connectors X8 X2 X8 Z004 X1 X7 X6 X5 X4 X3 X4 A001...
Page 19: ...19 Secondary rectifier Z002 Connectors X6 X5 X2 X1 X4 X3 X10 X9 X8 X7 X11...
Page 35: ...35 Notes...