background image

KEMPPI PRO EVOLUTION PROCOOL 30 / 0532 

© KEMPPI OY

5.   TECHNICAL DATA 

Cooling unit

Connection voltage  1 ~, 50/60 Hz 

400 V -15%...+20%

Connection capacity 

100 % ED 

120 W

Mains cable 

 

3 x 1.5 S - 0.8 m

Power factor  

   

0,42

Control voltage 

 

50 V DC

Cooling power 

 

1,25 kW

Start pressure, max. 

 

400 kPa

Cooling liquid 

 

20% - 40 % glycol/water

Reservoir volume 

 

ca. 3 l

Overall dimension: 

length 

610 mm

 

width 

230 mm

 

height 

290 mm

Weight  

 

13 kg

Operating temperature range 

 

-20 … +40 °C

Storage temperature range 

 

-40 … +60 °C

Degree of protection 

 

IP 23 C

The products meet the conformity requirements of CE-marking.

Summary of Contents for PRO EVOLUTION PROCOOL 30

Page 1: ...KEMPPI PRO EVOLUTION PROCOOL 30 Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1926411E 0532...

Page 2: ...g the machine 4 2 3 Serial number 4 2 4 Installation and main parts 4 2 4 1 Assembling the equipment 4 2 4 2 Main parts of cooling unit 4 2 5 Preparing for operation 5 3 OPERATION 5 3 1 Cooler operati...

Page 3: ...stalling operating and servicing the machine Welding arc and spatters Welding arc hurts unprotected eyes Be careful also with re ecting arc ash Welding arc and spatter burn unprotected skin Use safety...

Page 4: ...i cating the serial number is the only proper means of maintaining and identifying parts for a speci c product It is important to make correct reference to the serial number of the product when making...

Page 5: ...er pump starts to operate when the welding begins After the welding has stopped the pump will operate 1 to 5 minutes longer depending on the welding time During this time the liquid will cool down to...

Page 6: ...panel Check the liquid hoses for damages Remove any hose blockages Check water circulation add liquid if needed For further information and assistance contact your nearest Kemppi service workshop 4 4...

Page 7: ...Power factor 0 42 Control voltage 50 V DC Cooling power 1 25 kW Start pressure max 400 kPa Cooling liquid 20 40 glycol water Reservoir volume ca 3 l Overall dimension length 610 mm width 230 mm height...

Page 8: ...ntee does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide tu...

Page 9: ...076 5717 750 Telefax 076 5716 345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sale...

Reviews: