Seidentopf Binocular Head

The Cordless Comparison Scope has two eyepieces with a diopter

on one eyepiece to compensate for differential visual acuity between an
individual's eyes.  The Seidentopf binocular head allows adjustment for
interpupillary (interocular) adjustment.  The eyepieces will move to
exactly match the distance between the user's eyes.

Care and Maintenance

Your microscope is a fine precision instrument and should be treated

with care.  When not in use, it should be protected from dust by the plastic
cover provided.  Lenses and eyepieces should be cleaned periodically
with optical lens tissue which is soft and lint free.  Painted surfaces can be
cleaned with a moistened cloth.

Ken-A-Vision has quality technicians on staff to repair or service your

microscopes.  Ken-A-Vision recommends service every two years for
optimal life of the product.  Contact Ken-A-Vision at 1.816.353.4787,
Extension 5620 for more details.

Technical Specifications for Model No. T-192X Series
Microscopes

For the technical specifications on the Cordless Comparison Scope

visit the Ken-A-Vision Web site, www.ken-a-vision.com /t1922.asp

Equipment Rating: Description of Input Output
Connection

This is a 2.5 mm barrel style center pin, with a 5.5 volt, 300mA, output

supply which may be used with 110v, 220v, 230v, or 240v input systems.
The power supply /charger is made exclusively for the Ken-A-Vision
Cordless Microscope. Failure to use Ken-A-Vision parts, will void the war-
ranty of your microscope.

Summary of Contents for T-1922C

Page 1: ...Cordless Comparison Scope Instruction Manual T 1922C T 1924C...

Page 2: ...acro or opaque objects in a manner similar to a stereo or dissecting microscope Both are shipped as cordless units with an enclosed charger power cord adapter The T 1922C has 4x 10x and 40xR DIN objec...

Page 3: ...or left right split viewing X X Coarse and Fine Coaxial Focal Adjustment X X Supra Stage Incident Lighting Above Stage Light X X Sub Stage Transmitted Lighting Below Stage Light X Mechanical Stage X x...

Page 4: ...rench provided back off the set screws two or three turns until flush with the inside rim of the head socket of the base the points of these screws are initially visible back them off until they disap...

Page 5: ...l adjust the light intensity of the illuminator T 1924C There are two illuminators built into to each of the microscope bases one is sub stage and one is supra stage The supra stage illuminator is nec...

Page 6: ...oth the coarse focus large knob and fine focus small knob are on the same axis Having both sets of knobs on the same axis makes it easier to switch from one focus knob to the other without moving eyes...

Page 7: ...nted surfaces can be cleaned with a moistened cloth Ken A Vision has quality technicians on staff to repair or service your microscopes Ken A Vision recommends service every two years for optimal life...

Page 8: ...Y WARRANTY To replace the batteries loosen the silver thumbscrew in bottom of the base Drop the door down remove the battery cover and replace the batteries Accessories If you are interested in purcha...

Reviews: