background image

 www. kenall.com      P: 800-4-Kenall      F: 847-360-1781      1020 Lakeside Drive Gurnee, Illinois 60031    

1

INSTALLATION INSTRUCTIONS

CDL6VL2_F-5507_110514

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions 

should always be followed, including the following:

 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE 

APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH 

THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND 

THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS 

BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH 

ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT 

TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS 

AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. 

SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE 

FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING 

ORIENTATION, OR MOUNTING RESTRICTIONS. 

 

SAVE THESE INSTRUCTIONS

CDL6VL2 LED SERIES

SIMPLESEAL

™ 

DOWNLIGHTS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions 

should always be followed, including the following:

 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE 

APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH 

THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND 

THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS 

BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH 

ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT 

TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS 

AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. 

SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE 

FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING 

ORIENTATION, OR MOUNTING RESTRICTIONS. 

 

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

I.  Luminaire Mounting Procedure GRID FIXTURE

•   Cut an 8.125" diameter hole in ceiling 

panel and install panel.

•   Insert conduit or c-channel (by others) through 

mounting brackets. Bend brackets to secure.  
Lift fixture into ceiling through adjacent opening 
and position over cutout.

GENERAL 

This instruction sheet applies for the CDL6VL2, HADL6VL2, MDL6VL2, M2DL6VL2, and TDL6VL2 Downlight.

•   Disconnect power to all circuits before wiring system. 
•   Install in accordance with all national, state, and local codes. 
•   Be sure to connect LED luminaire’s chassis GROUND connection to a GROUNDED conductor wire.
•   Read all product markings and labels to ensure correct installation of a system. Supplemental instructions may  

be located on the fixture, in addition to this instruction sheet, regarding orientation or mounting restrictions.

This lighting system contains sensitive electronics. Take care to avoid damage by improper handling or static 
electricity discharge (ESD). Either type of damage could render the system inoperable or cause latent failure.

Figure 1