INSTALLATION INSTRUCTIONS
UC_F-5449_090418
Luminaires for Task Lighting Applications
STRATALUME
™
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH
THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL
CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE
WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT
CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE
MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION
OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED
ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET,
REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS.
FIXTURE IS INTENDED FOR UNDERCABINET OR UNDERSHELF
MOUNTING. FAILURE TO INSTALL ON A MECHANICALLY-SOUND
SURFACE MAY RESULT IN PERSONAL INJURY, FIXTURE DAMAGE,
OR POTENTIAL FIRE HAZARD. DO NOT INSTALL OUTDOORS OR
IN APPLICATIONS NOT INTENDED FOR USE. READ INSTRUCTIONS
PROVIDED WITH ANY STRATALUME CONNECTS
™
ACCESSORY.
THESE MAY OVERRIDE CERTAIN INSTALLATION PROCEDURES
FOR LUMINAIRE INSTALLATION
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
UC SERIES
This instruction sheet applies for the Stratalume UC Series UCDD, UCSD, UCDL and UCSL.
FIXTURE MOUNTING PROCEDURE
Before beginning, make sure all components have been unpacked from the shipping carton.
The Stratalume UC fixtures can be mounted individually only. Use the following steps to mount all Stratalume
UC fixtures:
1. Determine where fixture(s) will be mounted.
2. Ensure adequate clearance exists at the rear (or side) of the fixture for electrical connection with FMC or NM
wire.
3. For applications where electrical connection is made to a cord and plug (CP) allow an additional clearance for
side cord and plug will be installed.
INDIVIDUAL-MOUNT
4. Remove lens and electrical gear tray from fixture.
5. Refer to individual specification sheet for mounting dimensions for each fixture series or use base as template
to locate mounting positions.
6. Secure fixtures at opposite ends using two #8 screws. (UCDL,UCSL installation kit supplied)
Electrical Connection – Hardwired Units
MAKE SURE AC POWER IS OFF BEFORE MAKING ELECTRICAL CONNECTION TO FIXTURE(S).