KENCO Pipe Lift™ Operation Manual
9
170 State Route 271
Ligonier, PA 15658
1-800-653-6069
Section VI.
Maintenance
A.
Daily:
1.
Visually inspect Pipe Lift™ for signs of stress and wear.
2.
Check that bolts and nuts are snug.
3.
Check that key-way area of the attachment and lift body are properly seated.
4.
Ensure free movement of all components.
5.
Ensure that all warning labels are present and readable.
6.
Check that the actuator mounting screws are snug and seated.
7.
Lubricate all moving mechanisms with penetrating oil.
8.
LUBRICATE ACTUATOR WITH LIGHT PENETRATING OIL ONLY
(WD40™)
B.
Annually*
1.
Remove pivot bolts and coat with grease.
2.
Inspect holes, pins, bolts etc. for wear. See sect VII for criteria.
3.
Remove actuator, clean and lubricate with light penetrating oil – check for signs
of wear, replace if necessary.
*
Frequency depends on usage, environmental conditions, etc.