37
Click on the
Light and Imager Settings
hotkey in the
System
menu (Fig. 61). This will open the
Light
and Imager Settings
dialog. In this dialog you can change trigger settings on the
Trigger
tab,
exposure and gain settings on the
Imager Settings
tab and control illumination on the
Light Settings
tab. Select the
Trigger Settings
tab if it is not selected by default. In the
Trigger Type
droplist select
Burst (external)
, a
Burst Length
of five and an
Interval
of 500000 µs (one half second) (Fig.
62). With these settings, when the system is triggered it will take a maximum of five images with a
period of one half second between images. If a code is read before the image count reaches five,
the reader will stop triggering.
Fig. 61 - Light and Imager Settings Hotkey
Fig. 62 - Light and Imager Settings Dialog