Kendrion Kuhnke Automation GmbH 

Construction and Functionality 

 

Kuhnke Vico

 (

E 854 DE

) 

 

 

51 

28-03-2019 

 

10.9.2 Accessories 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Kuhnke Vico 1004

Page 1: ...User Manaual Kuhnke Vico 404 704 1004 Touch Panel with CODESYS HMI WEB Terminal with HTML 5 Browser E 854 DE 28 03 2019...

Page 2: ...escription 13 3 1 General Description 13 3 1 1 Applicability and Intended Use 14 3 2 Technical Data of Kuhnke Vico 15 3 2 1 Dimensions 15 4 Construction and Functionality 16 4 1 Brief Description 16 4...

Page 3: ...services 34 6 1 2 Restricting access 34 6 2 Splash Screen 34 7 CODESYS V3 Development Environment 35 7 1 Installing CODESYS on the Project Engineering PC 35 7 1 1 Installing the device description in...

Page 4: ...Table of Contents Kuhnke Vico E 854 DE 4 28 03 2019 10 6 1 EMC standards 48 10 7 Regulations and Declarations 49 10 7 1 Mark of conformity 49 10 8 Approvals 49 10 9 Order Specifications 50 10 9 1 Basi...

Page 5: ...the specific contract Claims for damages against us on whatever grounds are excluded except in instances of deliberate intent or gross negligence on our part 1 2 2 Terms of Delivery The general condi...

Page 6: ...omation GmbH Preface Kuhnke Vico E 854 DE 6 28 03 2019 1 2 4 Warranty Warranty is subject to the provisions of the conditions of sale of Kendrion Kuhnke Automation GmbH or any contractual agreements b...

Page 7: ...eloped and manufactured for standard industrial use They must not be used for any other purposes than the ones specified in the catalogue or the associated technical documentation Proper and safe oper...

Page 8: ...WARNING makes you aware of a potentially hazardous situation which MAY cause a serious or fatal accident or damage to this or other devices if not observed CAUTION A CAUTION alert makes you aware of a...

Page 9: ...a way as to exclude unintended operation Lay control cables such that interference inductive or capacitive is excluded if this interference could influence controller operation or its functionality M...

Page 10: ...VDE 0113 Electrical immission safeguard To eliminate electromagnetic interference connect the control system to the protective earth conductor Practice best cable routing Cable routing and wiring Keep...

Page 11: ...ces such as from relays contactors solenoids or switching magnets produces surge voltages It is necessary to reduce these extra voltages to a minimum Throttling elements could be diodes Z diodes varis...

Page 12: ...essor technology Safe investment by long term system availability Industry compliant interfaces CODESYS V3 HMI RTC Software Releases Software Options Option Identification Function CODESYS HMI CODESYS...

Page 13: ...oard with integrated touch screen allows users to run all display and operating functions in a single unit It is designed for on site use immediately at the machine Machine system and switching cabine...

Page 14: ...heat develops in the rear part of the unit Verify that the place of installation is ventilated properly NOTE Damage to the unit Choosing the wrong place of installation may cause damage to the unit Ch...

Page 15: ...abinet or control panel IP 54 or better Mounting position Horizontal and vertical Storage temperature 25 C 70 C Operating temperature 0 C 50 C if installed vertically 0 C 40 C if installed horizontall...

Page 16: ...rief Description 4 2 Labelling and Identification Name plate Default LAN address Type CODESYS HMI Order no 677 800 20 Ident 193634 Prot class front IP66 IP20 Def IP 192 168 000 204 Name plate and soft...

Page 17: ...above was manufactured on 05th June 2015 and has the serial number 00039 18 09 05 00039 Software licence identification Depending on your model variant different licence labels will be affixed to the...

Page 18: ...ring transport and storage Refer to manual section 3 2 Technical Data for admissible ambient and transport condition details The unit contains a permanently installed lithium metal button cell None of...

Page 19: ...wer supply unit must have external protection against short circuit and overload triggering at max 10 A Pin wiring 24 VDC power supply Pin Symbol Function 24V External power supply 24 VDC 10 V 32 V 0...

Page 20: ...interference received via external power supply cables signal cables or cables of peripheral units 4 5 3 Serial Port COM The port is not electrically insulated Use the software to switch it over Pin w...

Page 21: ...reen orange Data link LED RCV orange Activity Control and visualisation units are designed to control machines and unable to fend off external attacks When running these units in publicly accessible n...

Page 22: ...lowed only when no more file operations are being performed Failure to comply may render the USB stick useless If a program still has a file open when the USB stick is pulled you will find it impossib...

Page 23: ...stalling them 5 1 1 Location of installation The unit was not made for ongoing exposure to direct sunlight because this may make the film on the front panel age faster The unit was not made for ongoin...

Page 24: ...nough to ensure that the panel PC is mounted correctly at all times In order to achieve the specified ingress protection the material must not warp under the load of the mounting bolts or operation IP...

Page 25: ...o E 854 DE 25 28 03 2019 5 1 5 Mounting elements Insert the unit in the front panel opening and put in the mounting clips as shown in the drawing below Tighten the screws of the mounting clips to 75 N...

Page 26: ...ke heed of the specified conductor shielding check that all data link cables attached to the unit have shielded wires and attach to the unit s earthing terminals Information Earth wires should be shor...

Page 27: ...GmbH Construction and Functionality Kuhnke Vico E 854 DE 27 28 03 2019 Power supply fusing The cord must have external protection against short circuit and overload triggering at max 10 A min 60 V Po...

Page 28: ...touch stylus NOTE Damage to the touch screen by pointed or sharp objects Destruction of front Do not use pointed or sharp objects to operate the touch screen Avoid sudden or impact like touch screen...

Page 29: ...e operating system displays after the boot up routine Remember that the display resolution is set in the Image In case the unit is equipped with a CODESYS HMI it will start automatically and display i...

Page 30: ...ss LAN X3 192 168 0 204 Subnet mask 255 255 0 0 To connect to the unit for the first time mind that your PC s IP address must be in the same range as that of the unit This many involve changing your P...

Page 31: ...al effect and no functional constraint 5 5 2 Table of faults Table of faults Description Possible Cause Recommended Action Date and time were not stored permanently Discharged supercap buffer of real...

Page 32: ...system be sure to turn off Kuhnke Vico before you clean the front panel CAUTION Unintentional start of functions Movements of machine parts In order to avoid unintentionally starting a function by tou...

Page 33: ...ty apply Warranty expires if unauthorised attempts are made to repair the unit product or any other intervention is performed 5 7 3 Taking out of service disposal Before disposing of Kuhnke Vico you m...

Page 34: ...ry effort to avoid exposing the PLC and controller networks to open networks or the Internet Safeguarding should include extra data link layers such as remote access via VPN as well as sophisticated f...

Page 35: ...ardware matching the Windows version installed 7 1 1 Installing the device description in CODESYS V3 Before the IEC 61131 3 development tool can be used to operate a device CODESYS V3 is to be made kn...

Page 36: ...ibus DP modules or eds and dcf files of CAN devices Clicking on OK confirms your settings closes the screen and adds the device to the tree shown on screen Device Repository Look at the bottom of scre...

Page 37: ...of systems and machines 8 1 1 Settings The Settings page will welcome you when you start chromium browser for the first time Please note that you have to log in to be able to display the Setting page...

Page 38: ...su htm Tool Bar Enable Tool Bar Activated 9 Systems Settings 9 1 Activation of Systems Settings The configuration pages of the Vico Panel can be access in different ways 9 1 1 System setting during st...

Page 39: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 39 28 03 2019...

Page 40: ...03 2019 9 1 2 Using the Chromium browser s Setting page If the unit is set to running the browser at start up you can display the Settings page by keeping the top left corner of the touch screen pres...

Page 41: ...NMP and logging Management Update of BSP components Main OS Config OS Boot loader XLoader check for partitions consistence update of splash screen informations about usage and size of partitions The u...

Page 42: ...ing the software resources concerned CODESYS Control runtime system Equipment manufacturers installing the CODESYS runtime system on their devices are sent a licence file when they purchase the CODESY...

Page 43: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 43 28 03 2019 10 3 Connection Examples...

Page 44: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 44 28 03 2019 10 4 Dimensions 10 4 1 Kuhnke Vico 404...

Page 45: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 45 28 03 2019 10 4 2 Kuhnke Vico 704...

Page 46: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 46 28 03 2019 10 4 3 Kuhnke Vico 1004...

Page 47: ...film is highly resistant to abrasion and provides excellent chemical resistance to cleaning agents and solvents Solvent resistance After 1 2 hour of contact at 21 C not visibly affected by acetone bu...

Page 48: ...ct discharge severity 2 HF irradiation housing EN 61000 4 3 80 MHz 1000 MHz 10 V m 80 AM 1 kHz 1 4 GHz 2 0 GHz 3 V m 80 AM 1 kHz 2 GHz 2 7 GHz 1 V m 80 AM 1 kHz HF carried by wire EN 61000 4 6 150 kHz...

Page 49: ...le to the competent authorities pursuant to the above EU Directive Please contact the Project Management as necessary 10 8 Approvals Vico X04 has been granted the following approvals RoHS Conforms to...

Page 50: ...y resolution 800 480 WVGA ARM Cortex A8 1 GHz CODESYS V3 HMI Kuhnke Vico 1004 HMI 677 800 20 Touch Panel with CODESYS V3 HMI 10 1 display resolution 1024x600 WSVGA ARM Cortex A8 1 GHz CODESYS V3 HMI K...

Page 51: ...Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico E 854 DE 51 28 03 2019 10 9 2 Accessories...

Page 52: ...Kendrion Kuhnke Automation GmbH Industrial Control Systems L tjenburger Str 101 23714 Malente Tel 49 4523 402 0 Fax 49 4523 402 201 sales ics kendrion com www kendrion com...