Front Panel Opening
•
Cut an opening into the control panel area where you wish to install the unit. Refer to the appropriate
drawing or table to find the correct dimensions.
Front Panel Opening
Model
Width A
Height B
Vico MT 727
189.7 mm
121.5 mm
Vico MT 1027
252 mm
174.5 mm
Vico MT 1527
395.5 mm
244.5 mm
* Please note the drawing
7‘‘ display panels
•
Approaching the switching cabinet from the front, slide the unit into the opening and gently push it all the
way in until it contacts the cabinet front.
•
At the back: Place the mounting hardware (1) in the T slots on the side (2) and laterally slide them in (3)
until the snap into place.
•
Go to the first piece of mounting hardware in a corner and tighten the screw (4) until it pushes against
the cabinet panel. Tighten the screws to max. 0.2 Nm.
•
Repeat at the mounting element opposite and across.
•
Repeat the crosswise procedure on the remaining elements.
A
B