LP Tank Exchange
• Many retailers that sell grills offer you the option of replacing
your empty LP tank through an exchange service. Use only those
reputable exchange companies that inspect, precision fill, test
and certify their cylinders. Exchange your tank only for an OPD
safety feature-equipped tank as described in the "LP Tank"
section of this manual.
• Always keep new and exchanged LP tanks in upright position
during use, transit or storage.
• Leak test new and exchanged LP tanks BEFORE connecting to
grill.
Connecting Regulator To The LP Tank
1. LP tank must be properly secured onto grill. (Refer to
assembly section.)
2. Turn all control knobs to the OFF position.
3. Turn LP tank OFF by turning OPD hand wheel clockwise to a
full stop.
4. Remove the protective cap from LP tank valve. Always use
cap and strap supplied with valve.
ck
LP Tank Leak Test
For your safety
OPD Hand Wheel
Type 1 outlet with
thread on outside
Safety Relief Valve
Strap and Cap
• Leak test must be repeated each time LP tank is exchanged or
refilled.
• Do not smoke during leak test.
• Do not use an open flame to check for gas leaks.
• Grill must be leak tested outdoors in a well-ventilated area,
away from ignition sources such as gas fired or electrical
appliances. During leak test, keep grill away from open flames
or sparks.
• Use a clean paintbrush and a 50/50 mild soap and water
solution. Brush soapy solution onto areas indicated by arrows
in figure below. Leaks are indicated by growing bubbles.
Do not insert a POL transport plug
(plastic part with external
threads) into the type 1 valve
outlet. It will defeat the Safety
Relief Valve feature.
WARNING
If “growing” bubbles appear do not use or move the LP
tank. Contact an LP gas supplier or your fire department!
5. Hold regulator and insert nipple into LP
tank valve. Hand-tighten the coupling
nut, holding regulator in a straight line
with LP tank valve so as not to crossth-
thread the connection.
Nipple has to be
centered into the LP
tank valve.
6 • 146.53496710
▲
Do not use household cleaning agents. Damage to the gas
train components (valve/hose/regulator) can result.