![background image](http://html.mh-extra.com/html/kenmore/153-582400/153-582400_use-and-care-manual_187015027.webp)
27
* These instructions are brief and are intended as guidance for a quali
fi
ed service technician. If you lack the skills that are necessary
to perform these procedures, call the Sears Service Center for assistance (1-844-553-6667).
E09
with an alert Icon flashing.
E10
E11
E12
Electronic Thermostat (ET) error.
1. Turn off electrical power.
2. Check wiring at Electronic Thermostat (ET) for damage.
3. Turn on electrical power at breaker.
4. If this code flashes condition continues, replace the Electronic
Thermostat (ET).
E51
with an alert Icon flashing.
A failure to communicate with the Electronic
Thermostat (ET).
1. Turn off electrical power at the breaker, check all electrical con-
nections,
and wiring for damage.
2. Replace the Electronic Thermostat (ET).
3. Turn on electrical power at breaker.
E52
with an alert Icon flashing.
Energy Saver Module (ESM) is receiving the
wrong data from the Electronic Thermostat
(ET).
1. Turn off electrical power at the breaker, check all electrical con-
nections,
and wiring for damage.
2. Replace the Energy Saver Module (ESM), if this does not correct
the problem, also replace Electronic Thermostat (ET).
E71
with an alert Icon flashing.
Energy Saver Module (ESM) thermistor
failure.
1. Turn off electrical power at the breaker, check all electrical con-
nections,
and wiring for damage.
2. Turn on electrical power at breaker.
3. If error returns call service technician for assistance.
Summary of Contents for 153.582400