background image

Summary of Contents for 297208300

Page 1: ...ide Congelador Guia para su uso y cuidado Cong_lateur Guide d utilisation et d entretien Sears Roebuck and Co Hoffman Estates IL 60179 U S A Sears Canada inc Toronto Ontario Canada M5B 2B8 www sears com 297208300 September 2007 11 ...

Page 2: ...n Agreements 4 Installation 5 6 TemperatureControl 6 FreezerFeatures 7 EnergySavingTips 8 Power Failure Freezer Failure 8 Ice Service 9 Care Cleaning 10 Before YouCall 11 13 FOR YOUR SAFETY Do not store or use gasoline or other flammable liquids in the vicinity of this or any other appliance Read product labels for warnings regarding flammability and other hazards Do not operate the freezer in the...

Page 3: ...charge if defective in material or workmanship If thisappliance is used for other lhan private family purposes this warranty applies for only 90 days from the date of purchase This warranty covers only defects in material and workmanship Sears will NOT pay for 1 Expendable items that can wear out from normal use including but not limited to filters belts light bulbs and bags 2 A service technician...

Page 4: ...st help by phone we call it Rapid Resolution phone support from a Sears representative on all products Think of us as a talking owner s manual Power surge protection against electrical damage due to power fluctuations _ 250 Food Loss Protection annually for any food spoilage that is the result of mechanical failure of any covered refrigerator or freezer _ Rental reimbursement if repair of your cov...

Page 5: ... Level Freezer After discarding crating screws PIASTIC LEVELING FEET and wood CRATING base use a SCREW carpenter s level to level the freezer from front to back Adjust the plastic leveling feet in front V2 J_J _ DISCARD THE 4 CRATING bubble higher SCREWS ANO _ woo0 BASES SOthat the door _ closes easily when left halfway open Leveling Instructions for all Refrigerator Freezer Pair Remove two leg le...

Page 6: ...completely The freezer will run continuously for the first several hours Foods that are already frozen may be placed in the freezer after the first few hours of operation Unfrozen foods should NOT be loaded into the freezer until the freezer has operated for 4 hours When loading the freezer freeze only 3 pounds of fresh food per cubic foot of freezer space at one time Distribute packages to be fro...

Page 7: ...elves for shipping may be removed and discarded Tilt Out Shelf Adjustable interior Shelves Upright Models TO ADJUST CANTILEVER SHELVES Lift front edge up Pull shelf out Replace the shelf by inserting the hooks at rear of the shelf into the wall bracket Lower the shelf into the desired slots and lock into position MiD LEVEL LIGHT The light comes on automatically when the door is opened To replace t...

Page 8: ...locking it open if necessary to prevent odor and mold growth Moving When moving the freezer follow these guidelines to prevent damage Disconnect the power cord plug from the wall outlet Remove foods then defrost and clean the freezer Secure all loose items such as base panel baskets and shelves by taping them securely in place to prevent damage In the moving vehicle secure freezer in an upright po...

Page 9: ...OFF position The ice maker also turns off automatically when the ice container is full If your model has an adjustable freezer shelf place the shelf in the lower position so that the wire signal arm will hit the ice when the container is full ICE MAKER TIPS Leveling Bracket Container 1 or less Ice cubes stored too long may develop an odd flavor Empty the ice container and ensure that the wire sign...

Page 10: ...r Do not wash any removable items bins drawers etc in dishwasher Allow glass to warm to room temperature before immersing in warm water Soap and water Glass cleaner Mild liquid sprays Soap and water Non Abrasive Glass Cleaner Soap and water Ammonia Stainless Steel Cleaners Do not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smooth handles Do Not u...

Page 11: ... have been stored recently Freezer has recently been disconnected for a period of time The external freezer walls can be as much as 30 F warmer than room temperature Ensure plug is tightly pushed into outlet Check replace fuse with a 15 amp time delay fuse Reset circuit breaker Check house lights Call local Electric Company It s normal for the freezer to work harder under these conditions It takes...

Page 12: ...t used to cool freezer is circulating throughout the system Freezer is not level It rocks on the floor when it is moved slightly Floor is uneven or weak Freezer rocks on floor when it is moved slightly Freezer is touching the wall Freezer Weather is hot and humid which increases internal rate of frost build up Door may not be seating properly Door is kept open too long or is opened too frequently ...

Page 13: ... freezer Ice maker is not working This condition can force the cabinet out of square and mJsalign the door Refer to Leveling in the Installation Section Level the floor by using wood or metal shims under the freezer or brace floor supporting the freezer I Follow directions under lnterior Light or Mid Level Light in the Freezer Features Section See Freezer Does Not Run in the Before You Call Sectio...