KENMORE ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Electrical Connection

It is the responsibility and obligation of the consumer to
contact a qualified installer to assure that the electrical
installation is adequate and is in conformance with the
National Electrical Code ANSI/NFPA No. 70-latest
edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local codes and ordinances.

Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows.

Electrical ground is required on this appliance.

 This appliance is equipped with a

copper conductor flexible cable. If connection is
made to aluminum house wiring, use only special
connectors which are approved for joining copper
and aluminum wires in accordance with the
National Electrical Code and local codes and
ordinances. Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Follow the connector manufacturer
recommended procedure closely.

This appliance is manufactured with a white neutral
power supply wire and a frame connected green or bare
copper grounding wire.

 DO NOT ground to a gas supply pipe.

DO NOT connect to electrical power supply until
appliance is permanently grounded. Connect the
ground wire before turning on the power.

Figure 4

3-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

Black
Wires

Junction
Box

Cable from appliance

Ground Wire
(Bare or Green Wire)

White Wire
(Neutral)

U.L.-Listed Conduit
Connector (or CSA listed)

Red

Wires

White Wire
(Neutral)

Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see figure 4):

1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box,

connect appliance and power supply cable wires as
shown in figure 4.

 You may not ground the cooktop

through the neutral (white) wire if cooktop is used
in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicle, or where local
codes do not permit grounding through the neutral
(white) wire. When grounding through the neutral
(white) wire is prohibited, you must use a 4-wire
power  supply cable. See Figure 5. Failure to heed
this warning may result in electrocution or other
serious personal injury.

Summary of Contents for 36"

Page 1: ...ance between cooktop and overhead cabinetry is 30 76 2 cm WARNING Figure 1 P N 318201438 0603 Rev A A B C E F G H D Cooktop Dimensions 30 76 2 cm min for unprotected cabinet and 24 61 cm min for cabinet with protected bottom surface Cooktop Cutout Dimensions 30 Min 76 2 cm For Standard Installation 35 1 8 89 2 cm 1 2 5 cm 4 X 8 10 2 cm x 20 3 cm opening to route armoured cable 7 18 4 cm Note D E a...

Page 2: ...back of the cooktop Do not slide unit into cabinet cutout Protruding screws on the bottom of unit may damage the bottom front finish 30 76 2 cm min for unprotected cabinet and 24 61 cm min for cabinet with protected bottom surface Note D E are critical to the proper installation of the cooktop D reflects the finished dimension Due to the variation in countertop materials it is recommended to first...

Page 3: ...in Clearance Between the Top of the Cooking Platform and the Bottom of an Unprotected Wood or Metal Cabinet 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1 8 Flame Retardant Millboard Covered With Not Less Than No 28 MGS Sheet Steel 0 015 0 4 mm Stainless Steel 0 024 0 6 mm Aluminum or 0 020 0 5 mm Copper Approximate Location of Junction Box 18 45 7 cm It is not r...

Page 4: ...ct the wire to the circuit panel at this time Electrical Requirements Observe all governing codes and local ordinances 1 A 3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line time delay fuse or circuit breaker is recommended DO NOT fuse neutral The fuse size must not exceed the circuit rating of the...

Page 5: ...manufacturer recommended procedure closely This appliance is manufactured with a white neutral power supply wire and a frame connected green or bare copper grounding wire DO NOT ground to a gas supply pipe DO NOT connect to electrical power supply until appliance is permanently grounded Connect the ground wire before turning on the power Figure 4 3 WIRE GROUNDED JUNCTION BOX Cable from Power Suppl...

Page 6: ...ing The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone Cooktop Installation 1 Visually inspect the cooktop for damage 2 If you are installing the optional Stainless Steel backsplash first fix it at the back of the cooktop using the screws supplied with the Kit and follow the instructions attached 3...

Page 7: ...t de 30 76 2 cm Figure 1 A B C E F G H D Minimum de 30 76 2 cm pour armoire non protégée Minimum de 24 61 cm pour surface protégée Ne glissez pas l appareil dans le comptoir Les vis qui dépassent sous l appareil pourraient endommanger l armoire Note D E sont des dimensions critiques pour une installation adéquate de la table de cuisson Assurez vous de respecter ces dimensions D reflète une dimensi...

Page 8: ...ate de la table de cuisson Assurez vous de respecter ces dimensions D reflète une dimension finale Étant donné la variation dans le matériel du comptoir il est recommandé de tailler un peu plus petit que cette dimension et l ajuster lors de l installation de l appareil Ouverture de 4 X8 10 2 cm x 20 3 cm pour l entrée de gaz Ne faites pas glisser l appareil dans l ouverture du comptoir Les vis qui...

Page 9: ...dable d un minimum de 0 015 0 4 mm d aluminium de 0 024 0 6 mm ou de cuivre de 0 020 0 5 mm Dégagement minimum de 30 76 2 cm entre le haut de la surface de cuisson et la base de l armoire en bois ou en métal non protégée L armoire supérieure ne doit pas excéder une profondeur maximale de 13 33 cm Emplacement approximatif de la boîte de jonction Minimum de K du rebord de la plaque de cuisson au mur...

Page 10: ...ou 120 208 Volts AC du panneau électrique à la plaque de cuisson Ne branchez pas encore le câble au panneau de circuits Exigences électriques Observez tous les règlements et les codes locaux applicables 1 Un câble électrique à 4 fils de 120 240 ou 120 208 Volts monophasé 60 Hz CA est requis sur un circuit séparé muni d un fusible sur chaque fil conducteur fusible temporisé ou disjoncteur recommand...

Page 11: ...uivant bien attentivement les directives recommandées par le fabricant Cet appareil est fabriqué avec un fil d alimentation neutre blanc et un fil dénudé en cuivre de mise à la terre connecté au châssis NE PAS utiliser un tuyau à gaz pour la mise à la terre NE PAS raccorder l appareil tant que sa mise à la terre n est pas complétée Raccordez les fils de mise à la terre avant de mettre l appareil s...

Page 12: ...st endommagée 2 Si vous installez le dosseret optionnel en acier inoxydable fixez le à l arrière de la table de cuisson à l aide des vis fournies et suivez les instructions fournies avec le dosseret Allez à l étape 3 si vous procédez à une installation standard c est à dire sans dosseret optionnel 3 Insérez la table de cuisson dans la découpe sur le dessus du comptoir NOTE N utilisez pas de pâte à...

Reviews: