background image

Summary of Contents for 4812

Page 1: ...e stability of the floor Dimensions that are shown must be used Given dimensions provide minimum clearance Contact surface must be solid and level Refer to your serial plate for applicable agency certifications Provide Proper Fuel Type Before Proceeding Your range is preset to operate on Natural Gas only important Note to the Consumer Keep these instructions with your Use Care Guide for future ref...

Page 2: ...or covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not installthe range over carpeting unless you place an insulating pad or sheet of 1 4 inch thick plywood between the range and carpeting Make sure the wall coverings around the range can withstand the heat generated by the range Do not obstruct the flow of combustion air at the oven ven...

Page 3: ...g tape Fig 14 Pipe joint sealant that resists action of LP Propane gas Fig 15 Gas line manual shut off valve Fig 16 1 2 NPT 90 black pipe elbow Fig 17 A new flexible metal appliance conduit 1 2 N PT x 3 4 or 1 2 I D must be design certified by CSA International Fig 18 Because solid pipe restricts moving the range we recommend using a new flexible conduit 48 MAXIMUM LENGTH for each new installation...

Page 4: ...m Minimum on depth for cabinets either side of above ramge top 30 Cabinet Opening width Back Wall Fig A Back Wall Fig B Install a flush mount 240V 40 50 ampere electrical wall outlet in the shaded area Do not seal the range to side cabinets Do not pinch the power supply cord between the range and the wall If cabinet depth is greater than 25 the oven front frame must extend beyond cabinet front by ...

Page 5: ...allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 24 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from wall when in...

Page 6: ...partment Excess wire inthe range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard ifwires become pinched Connect only as instructed under WIRING INSTRUCTIONS in Step Bofthe Installation Steps When using flexibleconduit or range cable use flex connector or range cable strain relief See Fig 32 on page 7 NOTE Only usecopper wire in conn...

Page 7: ...home requires 4 Wire connection Power cord instructions 1 Followthemanufacturer sinstallationinstructions supplied with the strain relief and install Also see Figs 29 30 31 32 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Elec...

Page 8: ... a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source For 3 4 Wire permanent connections ONLY 3 Wire permanent connection follow Steps 1 2 5 below 4 Wire permanent connection follow Steps 1 thru 5 below Before wiring the range review the suggested power source location drawings in Fig A B If connecting to a 4 Wire elec...

Page 9: ...ground strap from frame of the appliance Cut and discard the copper strap from the terminal block KEEP the ground screw ground plate and go to Step 4 4 4 Wire Permanent Connection ONLY Connectthe ground wire lead Green to the frame of the appliance using the ground screw plate as shown in Fig 36 Be sure to install using the same hole in the frame where the ground screw was originally installed 5 3...

Page 10: ...system during any pressure testing of that system at test pressures greater than 14 of water column pressure approximately 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 14 of water column pressure approximately 1 2 psig Seal...

Page 11: ...ide Burner Heads Fig 38 5 Match the letters stamped on Burner Skirts with Burner Heads and Burner Caps See Fig 38 Replace the Burner Heads and Caps on cooktop See Fig 38 Carefully align the Electrodes into slot or hole of each Burner Head Fig 38 Note The Burner Heads should sit flat on Cooktop Burner Skirts 6 Unpack Burner Grates and position on the cooktop REMEMBER DO NOT ALLOW SPILLS FOOD CLEANI...

Page 12: ...he range and check gas connections for leaks See anti tip instructions for proper anti tip anchoring instructions Before you call for service Refer to the Use Care Guide for cleaning instructions If removing the range is necessary for cleaning or maintenance shut off the gas supply Disconnect the gas and electrical supply If the gas or electrical supply is inaccessible lift the range slightly at t...